| 전자부품 데이터시트 검색엔진 |
|
AT83SND1CXXX-ROTIL 데이터시트(PDF) 139 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
AT83SND1CXXX-ROTIL 데이터시트(HTML) 139 Page - ATMEL Corporation |
|
139 / 212 page ![]() 139 4109J–8051–10/06 AT8xC51SND1C Notes: 1. These frequencies are achieved in X1 mode, F PER = FOSC ÷ 2. 2. These frequencies are achieved in X2 mode, FPER = FOSC. 17.4.5 Baud Rate Selection (Mode 2) In mode 2, the baud rate can only be programmed to 2 fixed values: 1/16 or 1/32 of the periph- eral clock frequency. As shown in Figure 17-14 the selection is done using SMOD1 bit in PCON register. Figure 17-15 gives the baud rate calculation formula depending on the selection. Figure 17-14. Baud Rate Generator Selection (Mode 2) Figure 17-15. Baud Rate Formula (Mode 2) 17.5 Multiprocessor Communication (Modes 2 and 3) Modes 2 and 3 provide a ninth-bit mode to facilitate multiprocessor communication. To enable this feature, set SM2 bit in SCON register. When the multiprocessor communication feature is enabled, the serial Port can differentiate between data frames (ninth bit clear) and address frames (ninth bit set). This allows the AT8xC51SND1C to function as a slave processor in an environment where multiple slave processors share a single serial line. When the multiprocessor communication feature is enabled, the receiver ignores frames with the ninth bit clear. The receiver examines frames with the ninth bit set for an address match. If the received address matches the slaves address, the receiver hardware sets RB8 and RI bits in SCON register, generating an interrupt. The addressed slave’s software then clears SM2 bit in SCON register and prepares to receive the data Bytes. The other slaves are unaffected by these data Bytes because they are waiting to respond to their own addresses. 9600 1 1 178 0.16 1 1 152 0.16 1 1 126 0.16 4800 1 1 100 0.16 1 1 48 0.16 1 0 126 0.16 Baud Rate F PER = 12 MHz (2) F PER = 16 MHz (2) F PER = 20 MHz (2) SPD SMOD1 BRL Error % SPD SMOD1 BRL Error % SPD SMOD1 BRL Error % 0 1 SMOD1 PCON.7 PER CLOCK ÷ 2 ÷ 16 To Serial Port Baud_Rate= 32 2 SMOD1 ⋅ F PER |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |