| 전자부품 데이터시트 검색엔진 |
|
PCF8535 데이터시트(PDF) 26 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCF8535 데이터시트(HTML) 26 Page - NXP Semiconductors |
|
26 / 52 page ![]() 1999 Aug 24 26 Philips Semiconductors Objective specification 65 × 133 pixel matrix driver PCF8535 7.16.5 SPECIAL FEATURE COMMAND PAGE 7.16.5.1 State control DM Direct mode allows VLCDOUT to be sourced directly from VDD2. This may be useful in systems where VDD is to be used for VLCD. DOF Display off will turn off all internal analog circuitry that is not required for temperature measurement. As a consequence the display will be turned off. This mode is only required if temperature measurements are required whilst in power-down mode. 7.16.5.2 Oscillator setting The internal oscillator may be disabled and the source clock for the display derived from the OSC pad. It is important to remember that LCDs are damaged by DC voltages and that the clock, whether derived internally or externally, should never be disabled whilst the display is active. The internal oscillator is switched off during power-down mode. When using an external clock and disabling it during power-down mode will further reduce the standby current. If it is not possible to disable it externally then it is worth noting that by selecting the internal clock, which is disabled during power-down mode, the same effect may be achieved. 7.16.5.3 COG/TCP The chip may be mounted on either a glass, foil or tape carrier package. For these applications, different organizations of the row pads are required to negate the necessity of routing under the device. The TRS and BRS allow for this swapping. The behaviour of both of these bits is further described in Section 7.15. 7.16.6 INSTRUCTION SET Table 16 Instruction set INSTRUCTION D/CR/W(1) I2C-BUS COMMAND BYTE I2C-BUS COMMANDS DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 H[2:0] = XXX; RAM read/write command page Write data 1 0 D7 D6 D5 D4 D3 D2 D1 D0 writes data to display RAM Read status 0 1 D7 D6 D5 D4 D3 D2 D1 D0 returns result of temperature measurement NOP 00 00000000no operation Default H[2:0] 0 0 0 0 000001 jump to H[2:0] = 111 H[2:0] = 111; function and RAM command page Command page 0 0 0 0 001H2 H1 H0 select command page Function set 0 0 0 0 010PD V 0power-down control, data entry mode RAM page 0 0 0 0 100XM0 0 0 set RAM page for X address Set Y address of RAM 00 0100Y3 Y2 Y1 Y0 sets Y address of RAM 0 ≤ Y ≤ 8 Set X address of RAM 00 1X6 X5 X4 X3 X2 X1 X0 sets X address of RAM 0 ≤ X ≤ 127 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |