| 전자부품 데이터시트 검색엔진 |
|
R2023K 데이터시트(PDF) 14 Page - RICOH electronics devices division |
|
|
|||||||||||||||||||||||||||||
R2023K 데이터시트(HTML) 14 Page - RICOH electronics devices division |
|
14 / 50 page ![]() R2023K/T 14 *1), *2) When the oscillation adjustment circuit is used, the interrupt cycle will fluctuate once per 20sec. or 60sec. as follows: Pulse Mode: The “L” period of output pulses will increment or decrement by a maximum of ±3.784 ms. For example, 1-Hz clock pulses will have a duty cycle of 50 ±0.3784%. Level Mode: A periodic interrupt cycle of 1 second will increment or decrement by a maximum of ±3.784 ms. • Control Register 2 (Address Fh) D7 D6 D5 D4 D3 D2 D1 D0 VDSL VDET XST PON CLEN1 CTFG WAFG DAFG (For Writing) VDSL VDET XST PON CLEN1 CTFG WAFG DAFG (For Reading) 0 0 Indefinite 1 0 0 0 0 Default Settings *) *) Default settings: Default value means read / written values when the PON bit is set to “1” due to VDD power-on from 0 volts. (1) VDSL VDD Supply Voltage Monitoring Threshold Selection Bit VDSL Description 0 Selecting the VDD supply voltage monitoring threshold setting of 1.6v. (Default) 1 Selecting the VDD supply voltage monitoring threshold setting of 1.3v. The VDSL bit is intended to select the VDD supply voltage monitoring threshold settings. (2) VDET Supply Voltage Monitoring Result Indication Bit VDET Description 0 Indicating supply voltage above the supply voltage monitoring threshold settings. (Default) 1 Indicating supply voltage below the supply voltage monitoring threshold settings. Once the VDET bit is set to 1, the supply voltage monitoring circuit will be disabled while the VDET bit will hold the setting of 1. The VDET bit accepts only the writing of 0, which restarts the supply voltage monitoring circuit. Conversely, setting the VDET bit to 1 causes no event. (3) XST Oscillation Halt Sensing Monitor Bit XST Description 0 Sensing a halt of oscillation 1 Sensing a normal condition of oscillation The XST accepts the reading and writing of 0 and 1. The XST bit will be set to 0 when the oscillation halt sensing. The XST bit will hold 0 even after the restart of oscillation. (4) PON Power-on-reset Flag Bit PON Description 0 Normal condition 1 Detecting VDD power-on -reset (Default) The PON bit is for sensing power-on reset condition. * The PON bit will be set to 1 when VDD power-on from 0 volts. The PON bit will hold the setting of 1 even after power-on. * When the PON bit is set to 1, all bits will be reset to 0, in the Oscillation Adjustment Register, Control Register 1, and Control Register 2, except XST and PON. As a result, INTR pin stops outputting. * The PON bit accepts only the writing of 0. Conversely, setting the PON bit to 1 causes no event. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |