Back Button L9800 Datasheet HTML 18Page - STMicroelectronics L9800 Datasheet HTML 19Page - STMicroelectronics L9800 Datasheet HTML 20Page - STMicroelectronics L9800 Datasheet HTML 21Page - STMicroelectronics L9800 Datasheet HTML 22Page - STMicroelectronics L9800 Datasheet HTML 23Page - STMicroelectronics L9800 Datasheet HTML 24Page - STMicroelectronics L9800 Datasheet HTML 25Page - STMicroelectronics L9800 Datasheet HTML 26Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 55 page
background image
6.1.9
Low operating power-on VDDIO
When the VDDIO supply voltage drops in the range indicated by VDDIO(UV), the bit STA_1.VDDIO_UV is set to
“1”. This is valid if the digital NPOR is ‘1’. For all conditions that generate an NPOR = 0, a dedicated clear on read
STA_1. NPOR bit is set. As soon as VDDIO overcomes the minimum of the voltage operative threshold
VDDIO(UV_RECOVERY) the bit STA_1.VDDIO_UV is set to “0” after the first clear on read.
One of the following conditions generates the NPOR condition (reset of the whole internal logic):
1. General internal supply failure (internal 3.3 V supply in UV or bandgap reference not correct)
2. VDDIO < VDDIO(UV) AND IN1 = 0 AND IN0 = 0
6.1.10
Power-down
The power-down condition is satisfied if both supply voltages undergo 3 V or, if at least one of them is applied to
the device in its operative range, the INn and IDLE pins are all set to “low”. If one or more channels are switched
on before power-down, it is necessary to assert a reset to ensure a correct turn-off timing. All possible power-
down scenarios are described here below:
Figure 14. Scenario 1 power-down
VBATT
VDDIO
IDLE
POR
V3V3
V1V2
t
V
Scenario 1: power-down with both supplies dropping together under 3 V. Although IDLE is high internal supply
reference and vbg drop; POR is set to zero. IN0 = IN1 = 0 V.
Figure 15. Scenario 2 power-down
VBATT
VDDIO
IN0
POR
t
V
V3V3
V1V2
Scenario 2: power-down with both supplies dropping together under 3 V. Although IN0 is high internal supply
reference and vbg drop; POR is set to zero. IDLE = IN1 = 0 V.
L9800
Power supply
DS14041 - Rev 2
page 22/55



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com