153 / 178 page ![]() 17.1.2 Power supply electrical characteristics 5.5V ≤ VBATP≤ 19V; -40°C ≤ Tj ≤ 175°C unless otherwise noticed. All voltages refer to GND pin. Table 62. Power supply electrical characteristics Symbol Parameter Test condition Min Typ Max Unit Pin VDD3-4 monitor t_an_chop_clock analog chopping period Guaranteed by scan 58 64 70 µs - 17.1.3 Power supply error handling Table 63. Power supply error handling Type of error Detection condition Action Clear SPI flag Restart condition VDD3 VDD3 under voltage self test fail On state, enabled through SPI bit VDDx UV/OV Self Test Enable (16) in SERVENA register Same as regulator fault detection, with additional VDDx OV/UV Self Test bit (10) set in SERVFLT register Clear on read Same as functional, self test enable to be re- enabled VDD3 over voltage self test fail On state, enabled through SPI bit VDDx UV/OV Self Test Enable (16) in SERVENA register Same as regulator fault detection, with additional VDDx OV/UV Self Test bit (10) set in SERVFLT register Clear on read Same as functional, self test enable to be re- enabled VDD4 VDD4 under voltage self test fail On state, enabled through SPI bit VDDx UV/OV Self Test Enable (16) in SERVENA register Same as regulator fault detection, with additional VDDx OV/UV Self Test bit (10) set in SERVFLT register Clear on read Same as functional, self test enable to be re- enabled VDD4 over voltage self test fail On state, enabled through SPI bit VDDx UV/OV Self Test Enable (16) in SERVENA register Same as regulator fault detection, with additional VDDx OV/UV Self Test bit (10) set in SERVFLT register Clear on read Same as functional, self test enable to be re- enabled 17.2 Internal supply monitor 17.2.1 Reference Oscillator A second trimmed 16 MHz oscillator runs in parallel with the main one and it is used to monitor its accuracy, if a frequency drift on any of the two oscillators happens a power down sequence is triggered with consequent reset generation and channel disabled; safe state lasts until the fail is recovered or the device is restarted by toggling of the wake pin. After system restart, if the fail is still present, the device enters the safe state condition again. Basic implementation of clock monitor is shown in the following figure. L9300 Functional safety DS12258 - Rev 5 page 153/178 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |