| 전자부품 데이터시트 검색엔진 |
|
M41T83RM6F 데이터시트(PDF) 20 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M41T83RM6F 데이터시트(HTML) 20 Page - STMicroelectronics |
|
20 / 64 page ![]() Clock operation M41T82, M41T83 20/64 DocID012578 Rev 19 3.1 Clock data coherency In order to synchronize the data during reads and writes of the real-time clock device, a set of buffer transfer registers resides between the I2C serial interface on the user side, and the clock/calendar counters in the part. While the read/write data is transferred in and out of the device one bit at a time to the user, the transfers between the buffer registers and counters occur such that all the bits are copied simultaneously. This keeps the data coherent and ensures that none of the counters are incremented while the data is being transferred. Figure 16. Clock data coherency 3.1.1 Example of incoherency Without having the intervening buffer/transfer registers, if the user began directly reading the counters at 23:59:59, a read of the seconds register would return 59 seconds. After the address pointer incremented, the next read would return 59 minutes. Then the next read should return 23 hours, but if the clock happened to increment between the reads, the user would see 00 hours. When the time was re-assembled, it would appear as 00:59:59, and thus be incorrect by one hour. By using the buffer/transfer registers to hold a copy of the time, the user is able to read the entire set of registers without any values changing during the read. Similarly, when the application needs to change the time in the counters, it is necessary that all the counters be loaded simultaneously. Thus, the user writes sequentially to the various buffer/transfer registers, then they are copied to the counters in a single transfer thereby coherently loading the counters. 32KHz OSC DIVIDE BY 32768 1 Hz READ / WRITE BUFFER-TRANSFER REGISTERS I2C I2C INTERFACE CENTURIES YEARS MONTHS DATE DAY-OF-WEEK HOURS MINUTES SECONDS COUNTER COUNTER COUNTER COUNTER COUNTER COUNTER COUNTER COUNTER 2 RTC COUNTERS AFTER A WRITE, DATA IS TRANSFERRED FROM BUFFERS TO COUNTERS AT START OF READ OR WRITE, DATA IN COUNTERS IS COPIED TO BUFFER/TRANSFER REGISTERS. WATCHDOG NON-CLOCK REGISTERS SQUAREWAVE CALIBRATION ALARM / HALT HALT BIT SET AT POWER-DOWN |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |