ADS101C01 데이터시트(PDF) 17 Page - Texas Instruments

부품명 ADS101C01
상세설명  ADS1x1S02 Ultra-Small, Low-Power, 12- and 16-Bit, 6 and 4kSPS ADCs With PGA, and Temperature Sensor
PDF  38 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  TI2 [Texas Instruments]
홈페이지  https://www.ti.com
Logo TI2 - Texas Instruments

ADS101C01 데이터시트(HTML) 17 Page - Texas Instruments

Back Button ADS101C01 Datasheet HTML 13Page - Texas Instruments ADS101C01 Datasheet HTML 14Page - Texas Instruments ADS101C01 Datasheet HTML 15Page - Texas Instruments ADS101C01 Datasheet HTML 16Page - Texas Instruments ADS101C01 Datasheet HTML 17Page - Texas Instruments ADS101C01 Datasheet HTML 18Page - Texas Instruments ADS101C01 Datasheet HTML 19Page - Texas Instruments ADS101C01 Datasheet HTML 20Page - Texas Instruments ADS101C01 Datasheet HTML 21Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 38 page
background image
8.5.5 Data Output and Data Ready (DOUT/DRDY)
DOUT/DRDY is a dual-function output pin. During SPI communication, conversion and register data are shifted
out on the rising edge of SCLK. This pin also functions as a data-ready indicator, that transitions low when a
conversion completes and new data are available. In multi-device systems where conversion completion must
be monitored across multiple devices on the SPI bus, periodically lower the CS to poll the DOUT/DRDY status of
the device. This method allows the system to identify which device has completed a conversion without requiring
dedicated interrupt lines for each device.
When operating in continuous-conversion mode, CS can be periodically pulled low to use DOUT/DRDY as
a data ready signal. If no data transfer occurs, DOUT/DRDY transitions high 8µs before the next conversion
completes. DOUT/DRDY can trigger a microcontroller to start reading data. This transition is shown in Figure
8-6. Complete the data transfer before DOUT/DRDY returns high, to avoid missing subsequent conversion
results.
CS
(1)
SCLK
DOUT/DRDY
DIN
Hi-Z
8µs
(1) In continuous-conversion mode CS can be held low. If CS is low, DOUT/DRDY asserts low indicating new data are available.
Figure 8-6. DOUT/DRDY Behavior Without Data Retrieval in Continuous-Conversion Mode With CS Held
Low
When CS is high, DOUT/DRDY is configured by default with a weak internal pullup resistor. This feature reduces
the risk of DOUT/DRDY floating near midsupply and causing leakage current in the controller. To disable this
pullup resistor and configure the pin as a true high-impedance output, set PULL_UP_EN = 0b.
8.5.6 Data Retrieval and Device Configuration
Data is written to and read from the ADS1x1S02 in the same manner for both single-shot and continuous-
conversion modes, without having to issue any commands.
The conversion data are always buffered, and retain the current data until replaced by new conversion data.
Data can be read at any time without concern of data corruption. When DOUT/DRDY asserts low, indicating that
new conversion data are ready, the conversion data are read by shifting the data out on DOUT/DRDY. The MSB
of the data on DOUT/DRDY is clocked out on the first SCLK rising edge. At the same time that the conversion
result is clocked out on DOUT/DRDY, new Configuration register data are latched on DIN on the SCLK falling
edge.
The WRITE_EN[1:0] bits control write access to the Configuration register. The Configuration register is updated
only when WRITE_EN[1:0] is set to 01b. All other bit combinations (00b, 10b, 11b) result in a no operation
command and prevents the Configuration register from being updated. When a no operation command occurs,
DIN data are ignored during SCLK pulses and the Configuration register remains unchanged.
The ADS1x1S02 offers direct readback of the Configuration register settings in the conversion data transmission
cycle. The Configuration register data readback transmission cycle consists of 32 bits for and is required
for 3-wire SPI mode when CS is tied to ground. When in 4-wire SPI mode the CS is controlled and is not
permanently tied low data transmission cycle can consist of 16 bits by taking CS line high after the 16th SCLK
cycle, or 32 bits when the Configuration register data readback is used.
www.ti.com
ADS101S02, ADS111S02
SLVSMZ0 – SEPTEMBER 2026
Copyright © 2026 Texas Instruments Incorporated
Submit Document Feedback
17
Product Folder Links: ADS101S02 ADS111S02



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com