Back Button ADS101C01 Datasheet HTML 25Page - Texas Instruments ADS101C01 Datasheet HTML 26Page - Texas Instruments ADS101C01 Datasheet HTML 27Page - Texas Instruments ADS101C01 Datasheet HTML 28Page - Texas Instruments ADS101C01 Datasheet HTML 29Page - Texas Instruments ADS101C01 Datasheet HTML 30Page - Texas Instruments ADS101C01 Datasheet HTML 31Page - Texas Instruments ADS101C01 Datasheet HTML 32Page - Texas Instruments ADS101C01 Datasheet HTML 33Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 38 page
background image
10.2 Typical Applications
10.2.1 K-Type Thermocouple with Thermistor Cold-Junction Compensation
The application example in Figure 10-6 shows how to use the ADS1x1S02 to monitor a K-Type thermocouple
using a linear PTC thermistor for cold-junction compensation.
3.3V
VDD
0.1µF
3.3V
1M
1M
3.3V
RBias
TMP61
10k
Thermocouple
RPU
RPD
0.3nF
0.3nF
3nF
CCM
CCM
CDIFF
1k
1k
RTC
RTC
500
RPTC
10nF
CPTC
ADS1x1S02
AIN0
AIN1
AIN3
PGA
12/16-Bit
ADC
1.024V
Voltage
Reference
GND
SPI
AIN2
SCLK
DIN
CS
DOUT/DRDY
Oscillator
Temperature
Sensor
Mux
Figure 10-6. K-Type Thermocouple Measurement Using a Thermistor for Cold-Junction Compensation
10.2.1.1 Design Requirements
Table 10-1 lists the design requirements for this application.
Table 10-1. Design Requirements
DESIGN PARAMETER
VALUE
Supply Voltage
3.3V
Thermocouple Type
K
Thermocouple Temperature Measurement Range
–200°C to +1250°C
Thermistor Type
PTC
Thermistor Temperature Measurement Range
–40°C to +125°C
Measurement accuracy at TA = 25°C(1)
±0.75
(1)
Not accounting for error of the thermocouple and cold-junction temperature measurement; offset
calibration at TTC = TCJ = 25°C; no gain calibration.
10.2.1.2 Detailed Design Procedure
In this thermocouple measurement example, biasing resistors RPU and RPD set the common-mode voltage of
the thermocouple to approximately mid-supply (VDD / 2) to keep the input voltages within the absolute input
voltage range of the PGA. These biasing resistors are also useful in detecting an open thermocouple. An open
thermocouple lead condition causes RPU and RPD to pull analog inputs AIN0 and AIN1 to VDD and GND
respectively. Consequently, the ADC reads a full-scale value outside the normal measurement range, indicating
a fault condition. Recommended values for RPU and RPD range from 1MΩ to 50MΩ to minimize self-heating and
measurement errors.
www.ti.com
ADS101S02, ADS111S02
SLVSMZ0 – SEPTEMBER 2026
Copyright © 2026 Texas Instruments Incorporated
Submit Document Feedback
29
Product Folder Links: ADS101S02 ADS111S02



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com