Back Button ADS101C01 Datasheet HTML 26Page - Texas Instruments ADS101C01 Datasheet HTML 27Page - Texas Instruments ADS101C01 Datasheet HTML 28Page - Texas Instruments ADS101C01 Datasheet HTML 29Page - Texas Instruments ADS101C01 Datasheet HTML 30Page - Texas Instruments ADS101C01 Datasheet HTML 31Page - Texas Instruments ADS101C01 Datasheet HTML 32Page - Texas Instruments ADS101C01 Datasheet HTML 33Page - Texas Instruments ADS101C01 Datasheet HTML 34Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 30 / 38 page
background image
Although the device digital filter attenuates high-frequency noise, further improvement can be achieved by
including a first-order passive RC filter at the input. The cutoff frequency of the differential filter (fC) created by
resistors RTC and capacitor CDIFF is calculated using Equation 6.
fC = 1 / 2π × RTC + RTC × CDIFF
(6)
Additionally, common-mode capacitors (CCM) provide attenuation of high-frequency common-mode noise. Select
values for common-mode capacitors at least 10 times smaller than the differential capacitor to prevent common-
mode noise conversion to differential noise.
The filter resistors RTC also serve as current-limiting resistors. These resistors limit the current into analog
inputs, AIN0 and AIN1, of the device to safe levels if an overvoltage on the inputs occurs. Care must be taken
when choosing the filter resistor values because the input currents flowing into and out of the device cause a
voltage drop across the resistors. This voltage drop shows up as an additional offset error at the ADC inputs.
The highest resolution is obtained when the largest expected thermocouple voltage is slightly below the full-scale
range of the ADC. For example, the maximum thermocouple voltage of a K-type thermocouple at TTC = 1250°C
with a cold-junction temperature TCJ = 0°C is approximately 50.644mV, as defined in the tables published by the
National Institute of Standards and Technology (NIST). If the cold junction drops below 0°C (minimum specified
at –40°C), the output voltage increases. At TCJ = –40°C, the output voltage becomes:
VTC=50.644mV− −1.527mV =52.171mV
(7)
The maximum gain that can be applied with the 1.024V reference is then calculated as (1.024V / 52.171mV) =
19.6. The next smaller PGA gain setting the device offers is 16.
The device incorporates an internal high-precision temperature sensor to measure the cold junction temperature.
Enable the internal temperature sensor by setting bit TS_EN = 1b. Optimal accuracy requires careful board
layout to provide efficient thermal coupling between the cold junction and the device package.
The device does not perform automatic cold junction compensation (CJC). Perform CJC within the host
controller using the following procedure:
1. Measure the thermocouple voltage, VTC, between AIN0 and AIN1.
2. Measure the cold junction temperature, TCJ, using the internal temperature sensor.
3. Convert TCJ to an equivalent thermocouple voltage (VCJ) using the NIST conversion tables.
4. Compute the total compensated voltage (VT = VTC + VCJ)
5. Convert the compensated voltage (VT) back to temperature using the NIST tables.
If the internal temperature sensor accuracy is insufficient or the device cannot be placed close enough to
the cold junction for good thermal measurement. Use the additional ADC input channels to measure the cold-
junction temperature externally using a thermistor or dedicated temperature sensor.
Figure 10-6 shows device uses AIN2 to measure a single-ended thermistor for cold junction compensation.
The Texas Instruments TMP61 linear thermistor is selected for the linearity and consistent sensitivity of the
device, enabling simple and accurate temperature-to-voltage conversion. A 10kΩ bias resistor is used with the
TMP61 to form a voltage divider matched to the TMP61 nominal resistance (10kΩ at 25°C). In this application
the thermistor is used for a more precise cold junction temperature measurement compared to the internal
temperature sensor of the ADS1x1S02.
ADS101S02, ADS111S02
SLVSMZ0 – SEPTEMBER 2026
www.ti.com
30
Submit Document Feedback
Copyright © 2026 Texas Instruments Incorporated
Product Folder Links: ADS101S02 ADS111S02



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com