| 전자부품 데이터시트 검색엔진 |
|
M306V2EEFS 데이터시트(PDF) 43 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M306V2EEFS 데이터시트(HTML) 43 Page - Renesas Technology Corp |
|
43 / 271 page ![]() Rev.1.40 Oct 06, 2004 page 43 of 269 M306V2ME-XXXFP, M306V2EEFP 0100 0 Invalid Division by 2 mode 1000 0 Invalid Division by 4 mode Invalid Invalid 0 1 0 Invalid Division by 8 mode 1100 0 Invalid Division by 16 mode 0000 0 Invalid No-division mode Invalid Invalid 1 Invalid 0 1 Low-speed mode Invalid Invalid 1 Invalid 1 1 Low power dissipation mode 2.5.7 Status Transition of BCLK Power dissipation can be reduced and low-voltage operation achieved by changing the count source for BCLK. Table 2.5.4 shows the operating modes corresponding to the settings of system clock control registers 0 and 1. After a reset, operation defaults to division by 8 mode. When shifting to stop mode, the main clock division select bit 0 (bit 6 at address 000616) is set to “1”. The following shows the operational modes of internal clock φ. (1) Division by 2 mode The main clock is divided by 2 to obtain the BCLK. (2) Division by 4 mode The main clock is divided by 4 to obtain the BCLK. (3) Division by 8 mode The main clock is divided by 8 to obtain the BCLK. Note that oscillation of the main clock must have stabilized before transferring from this mode to another mode. (4) Division by 16 mode The main clock is divided by 16 to obtain the BCLK. (5) No-division mode The main clock is used as the BCLK. (6) Low-speed mode fC is used as the BCLK. Note that oscillation of both the main and sub clocks must have stabilized before transferring from this mode to another or vice versa. At least 2 to 3 seconds are required after the sub clock starts. Therefore, the program must be written to wait until this clock has stabilized immediately after powering up and after stop mode is cancelled. (7) Low power dissipation mode fC is the BCLK and the main clock is stopped. Note: When switching the count source for BCLK between XIN and XCIN, it needs that the oscillation of the switched count source is sufficiently stable. Shift after taking the oscillation stabilizing time by software. CM17 CM16 CM07 CM06 CM05 CM04 Operating mode of BCLK Table 2.5.4 Operating modes dictated by settings of system clock control registers 0 and 1 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |