154 / 210 page ![]() APPLICATION 2.5 A-D converter 2-51 4513/4514 Group User’s Manual 2.5.2 A-D converter application examples (1) A-D conversion mode Outline: Analog input signal from a sensor can be converted into digital values. Specifications: Analog voltage values from a sensor is converted into digital values by using a 10- bit successive comparison method. Use the AIN0 pin for this analog input. Figure 2.5.2 shows the A-D conversion mode setting example. Fig. 2.5.2 A-D conversion mode setting example b3 b0 Disable Interrupts A-D interrupt is temporarily disabled. Interrupt enable flag INTE Interrupt control register V2 “0” ! ! All interrupts disabled (DI instruction) A-D interrupt occurrence disabled (TV2A instruction) 0 ! Set A-D Converter A-D conversion mode is selected to A-D operation mode. Analog input pin AIN0 is selected. A-D control register Q2 A-D conversion mode selected (TQ2A instruction) AIN0 selected (TQ1A instruction) A-D control register Q1 b3 b0 ! 0 b3 b0 0 0 ! 0 !! Clear Interrupt Request A-D interrupt activated condition is cleared. A-D conversion completion flag ADF “0” A-D conversion interrupt activated condition cleared (SNZAD instruction) Note when the interrupt request is cleared When is executed, considering the skip of the next instruction according to the flag ADF, insert the NOP instruction after the SNZAD instruction. When interrupt is not used When interrupt is used Set Interrupt Interrupts except A-D conversion is enabled (EI instruction) Set Interrupt A-D conversion interrupt temporarily disabled is enabled. b3 b0 1 !! ! Interrupt control register V2 A-D interrupt occurrence enabled (TV2A instruction) Interrupt enable flag INTE “1” All interrupts enabled (EI instruction) Start A-D Conversion A-D conversion operation is started (ADST instruction). When interrupt is not used When interrupt is used Check A-D Interrupt Request A-D conversion completion flag is checked (SNZAD instruciton) A-D Conversion Interrupt Occur Execute A-D Conversion High-order 8 bits of register AD → register A and register B (TABAD instruction) Low-order 2 bits of register AD → high-order 2 bits of register A (TALA instruction) “0” is set to low-order 2 bits of register A “!”: it can be “0” or “1.” When A-D conversion is executed by the same channel, to is repeated. When A-D conversion is executed by the another channel, to is repeated. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |