9 / 22 page ![]() DS1306 9 of 22 Table 3. TRICKLE CHARGER RESISTOR AND DIODE SELECT TCS Bit 7 TCS Bit 6 TCS Bit 5 TCS Bit 4 DS Bit 3 DS Bit 2 RS Bit 1 RS Bit 0 FUNCTION X X X X X X 0 0 Disabled X X X X 0 0 X X Disabled X X X X 1 1 X X Disabled 1 0 1 0 0 1 0 1 1 Diode, 2kΩ 1 0 1 0 0 1 1 0 1 Diode, 4kΩ 1 0 1 0 0 1 1 1 1 Diode, 8kΩ 1 0 1 0 1 0 0 1 2 Diodes, 2kΩ 1 0 1 0 1 0 1 0 2 Diodes, 4kΩ 1 0 1 0 1 0 1 1 2 Diodes, 8kΩ 0 1 0 1 1 1 0 0 Initial power-on state If RS is 00, the trickle charger is disabled independently of TCS. Diode and resistor selection is determined by the user according to the maximum current desired for battery or super cap charging. The maximum charging current can be calculated as illustrated in the following example. Assume that a system power supply of 5V is applied to VCC1 and a super cap is connected to VCC2. Also assume that the trickle charger has been enabled with one diode and resister R1 between VCC1 and VCC2. The maximum current IMAX would, therefore, be calculated as follows: IMAX = (5.0V - diode drop) / R1 (5.0V - 0.7V) / 2kΩ 2.2mA As the super cap charges, the voltage drop between VCC1 and VCC2 decreases and, therefore, the charge current decreases. POWER CONTROL Power is provided through the VCC1, VCC2, and VBAT pins. Three different power supply configurations are illustrated in Figure 4. Configuration 1 shows the DS1306 being backed up by a non-rechargeable energy source such as a lithium battery. In this configuration, the system power supply is connected to VCC1 and VCC2 is grounded. When VCC falls below VBAT the device switches into a low-current battery backup mode. Upon power-up, the device switches from VBAT to VCC when VCC is greater than VBAT + 0.2V. The device is write-protected whenever it is switched to VBAT. Configuration 2 illustrates the DS1306 being backed up by a rechargeable energy source. In this case, the VBAT pin is grounded, VCC1 is connected to the primary power supply, and VCC2 is connected to the secondary supply (the rechargeable energy source). The DS1306 operates from the larger of VCC1 or VCC2. When VCC1 is greater than VCC2 + 0.2V (typical), VCC1 powers the DS1306. When VCC1 is less than VCC2, VCC2 powers the DS1306. The DS1306 does not write-protect itself in this configuration. Configuration 3 shows the DS1306 in battery-operate mode, where the device is powered only by a single battery. In this case, the VCC1 and VBAT pins are grounded and the battery is connected to the VCC2 pin. Only these three configurations are allowed. Unused supply pins must be grounded. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |