| 전자부품 데이터시트 검색엔진 |
|
SX8661 데이터시트(PDF) 56 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SX8661 데이터시트(HTML) 56 Page - Semtech Corporation |
|
56 / 88 page ![]() ADVANCED COMMUNICATIONS & SENSING DATASHEET Revision v3.2, January 2011 © 2011 Semtech Corp. www.semtech.com 56 SX8661 Low Power, Capacitive Button Touch and Proximity Controller (8 sensors) with LED Drivers and Analog Output In case the debounce is enabled the SX8661 will count up to the number of debounce samples BtnCfg [1:0], BtnCfg [3:2] before taking a touch or release decision. The sample period is identical to the scan period. BtnAvgPosThresh Small environmental and system noise cause the ticks to vary slowly around the zero idle mode value. In case the ticks get slightly positive this is considered as normal operation. Very large positive tick values indicate a valid touch. The averaging filter is disabled as soon as the average reaches the value defined by BtnAvgPosThresh. This mechanism avoids that a valid touch will be averaged and finally the tick difference becomes zero. In case three or more sensors reach the BtnAvgPosThresh value simultaneously then the SX8661 will start an offset compensation procedure. Small environmental and system noise cause the ticks to vary slowly around the zero idle mode value. In case the ticks get slightly negative this is considered as normal operation. However large negative values will trigger an offset compensation phase and a new set of DCVs will be obtained. The decision to trigger a compensation phase based on negative ticks is determined by the value in the register BtnCompNegThresh and by the number of ticks below the negative thresholds defined in register BtnCompNegCntMax. An example is shown in Figure 54. Figure 54 Negative Ticks Offset Compensation Trigger BtnCompNegThresh Small negative ticks are considered as normal operation and will occur very often. Larger negative ticks however need to be avoided and a convenient method is to trigger an offset compensation phase. The new set of DCV will assure the idle ticks will be close to zero again. A trade-off has to be found for the value of this register. A negative threshold too close to zero will trigger a compensation phase very often. A very negative threshold will never trigger. BtnCompNegCntMax As soon as the ticks get smaller than the Negative Threshold the Negative Counter starts to count. If the counter goes beyond the Negative Counter Max then the offset compensation phase is triggered. The recommended value for this register is ‘1’ which means that the offset compensation starts on the first tick below the negative threshold. BtnHysteresis The hysteresis percentage is identical for all buttons. A touch is detected if the ticks are getting larger as the value defined by: |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |