7 / 22 page ![]() www.austriamicrosystems.com Revision 1.12 7 - 22 AS5050 Datasheet - Detailed Descr i p ti on 7.1.2 Reading an Angle The external microcontroller can respond to the INT request by reading the angle value from the AS5050 over the SPI interface. Once the angle value is read, the INT output is cleared again. Sending a “read angle” command by the SPI interface also automatically powers up the chip and starts another angle measurement. As soon ad the microcontroller has completed reading of the angle value, the INT output is cleared and a new result is stored in the angle register. The completion of the angle measurement is again indicated by setting the INT output and a corresponding flag in the status register. Reducing the Angle Jitter. Due to the measurement principle of the chip, only a single angle measurement is performed in very short time (~600µs) after each power-up sequence. As soon as the measurement of one angle is completed, the chip suspends to power-down state. An on-chip filtering of the angle value by digital averaging is not implemented, as this would require more than one angle measurement and consequently, a longer power- up time which is not desired in low-power applications. The angle jitter can be reduced by averaging of several angle samples in the external microcontroller. For example, an averaging of 4 samples reduces the jitter by 6dB (50%). 7.1.3 Low Power Mode After completing the readout of an angle value, the device is in very low power condition. The AS5050 remains in sleep mode until it receives another angle reading request over the SPI interface. The average power consumption therefore depends on the interval, at which the external controller reads an angle over the SPI Interface. The timing ratio between active and sleep phase: (EQ 1) Where: ton = Minimum on-time for power-up and angle measurement 600µs toff = Pause interval between measurements, determined by the polling rate of the external microcontroller Ion = Current consumption in active mode 8mA avg. Ioff = Current consumption in sleep mode 3µA Examples: 3000 measurements per second (continuous mode) I = 8mA 1000 measurements per second Iavg = 5mA 100 measurements per second Iavg = 500µA 10 measurements per second Iavg = 53µA Note: Even in low power mode, the power supply must be capable of supporting the active current at least for the time Ton, until the AS5050 is suspended to sleep mode. 7.1.4 Interrupt Chaining Every chip contains a configurable gate to combine its own internally generated interrupt signal with a signal applied externally over the XENINT- pin. The INT-mode register is preset via an OTP register can be overwritten by the SPI interface. Case A. Device A is set to mode 0 Device B is set to mode 0 The micro controller recognizes an interrupt if both devices signalize that the computation is finished. Case B. Device A is set to mode 0 Device B is set to mode 1 The micro controller recognizes an interrupt if one of the two devices signalize that the computation is finished. off on off off on on avg t t I t I t I + ∗ + ∗ = |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |