Back Button TLC320AD56 Datasheet HTML 26Page - Texas Instruments TLC320AD56 Datasheet HTML 27Page - Texas Instruments TLC320AD56 Datasheet HTML 28Page - Texas Instruments TLC320AD56 Datasheet HTML 29Page - Texas Instruments TLC320AD56 Datasheet HTML 30Page - Texas Instruments TLC320AD56 Datasheet HTML 31Page - Texas Instruments TLC320AD56 Datasheet HTML 32Page - Texas Instruments TLC320AD56 Datasheet HTML 33Page - Texas Instruments TLC320AD56 Datasheet HTML 34Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 30 / 42 page
background image
4–4
4.3.4.5
ADC Signal-to-Distortion+Noise, DVDD = 3 V (see Note 5)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VI = – 1 dB
78
VI = – 3 dB
79
84
VI = – 6 dB
76
81
Total harmonic distortion + noise (THD+N)
VI = – 9 dB
73
78
dB
VI = – 40 dB
42
47
VI = – 65 dB
17
22
VAUX = – 9 dB
73
78
NOTE 5: The test condition is a 1020-Hz input signal with an 8-kHz conversion rate. Input and output voltages are
referred to VDD /2.
4.3.5
ADC Channel
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VI(PP)
Peak-to-peak input voltage
6
V
Dynamic range
87
Interchannel isolation
110
dB
EG
Gain error
VI = – 1 dB at 1020 Hz
±0.3
EO(ADC)
ADC converter offset error
5
mV
CMRR
Common-mode rejection ratio at INM,
INP or AUXM, AUXP
VI = 0 dB at 1020 kHz
80
dB
Idle channel noise (on-chip reference)
30
75
µV rms
Ri
Input resistance
TA = 25°C
100
k
Ω
Channel delay
17/fs
s
4.3.6
DAC Path Filter, MCLK = 8.192 MHz, fs = 8 kHz (see Note 6)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
0 to 300 Hz
– 0.5
0.2
300 Hz to 3 kHz
– 0.25
0.25
Filter gain relative to gain at 1020 Hz
3.3 kHz
– 0.35
0.3
dB
Filter gain relative to gain at 1020 Hz
3.6 kHz
– 3
dB
4 kHz
– 40
≥ 4.4 kHz
– 74
NOTE 6: The filter gain outside of the passband is measured with respect to the gain at 1020 Hz. The input signal is the
digital equivalent of a sine wave (digital full scale = 0 dB). The nominal differential DAC channel output with
this input condition is 6 VI(PP). The –1 dB pass band is 0 to 3400 Hz for an 8-kHz sample rate. This pass band
scales linearly with the sample rate.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com