| 전자부품 데이터시트 검색엔진 |
|
CC1150-RTY1 데이터시트(PDF) 33 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
CC1150-RTY1 데이터시트(HTML) 33 Page - Texas Instruments |
|
33 / 67 page ![]() CC1150 SWRS037A Page 33 of 60 Description XOSC periods 26 MHz crystal Idle to TX/FSTXON, no calibration 2298 88.4 µs Idle to TX/FSTXON, with calibration ~21037 809 µs TX to IDLE, no calibration 2 0.1 µs TX to IDLE, including calibration ~18739 721 µs Manual calibration ~18739 721 µs Table 20: State Transition Timing 17 Data FIFO The CC1150 contains a 64 byte FIFO for data to be transmitted. The SPI interface is used for writing to the TX FIFO. Section 10.5 contains details on the SPI FIFO access. The FIFO controller will detect underflow in the TX FIFO. When writing to the TX FIFO, it is the responsibility of the MCU to avoid TX FIFO overflow. This will not be detected by the CC1150. A TX FIFO overflow will result in an error in the TX FIFO content. FIFO_THR Bytes in TX FIFO 0 (0000) 61 1 (0001) 57 2 (0010) 53 3 (0011) 49 4 (0100) 45 5 (0101) 41 6 (0110) 37 7 (0111) 33 8 (1000) 29 9 (1001) 25 10 (1010) 21 11 (1011) 17 12 (1100) 13 13 (1101) 9 14 (1110) 5 15 (1111) 1 Table 21: FIFO_THR Settings and the corresponding FIFO Thresholds The chip status byte that is available on the SO pin while transferring the SPI address contains the fill grade of the TX FIFO. Section 10.1 on page 19 contains more details on this. The number of bytes in the TX FIFO can also be read from the TXBYTES.NUM_TXBYTES status register. The 4-bit FIFOTHR.FIFO_THR setting is used to program the FIFO threshold point. Table 21 lists the 16 FIFO_THR settings and the corresponding thresholds for the TX FIFO. 8 bytes Underflow margin FIFO_THR=13 TXFIFO Figure 19: Example of FIFO at Threshold A flag will assert when the number of bytes in the FIFO is equal to or higher than the programmed threshold. The flag is used to generate the FIFO status signals that can be viewed on the GDO pins (see section 22 on page 37). Figure 19 shows the number of bytes in the TX FIFO when the threshold flag toggles, in the case of FIFO_THR=13. Figure 20 shows the flag as the FIFO is filled above the threshold, and then drained below. 6 7 8 9 6 7 8 9 10 NUM_TXBYTES GDO Figure 20: FIFO_THR=13 vs. Number of Bytes in FIFO |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |