53 / 72 page ![]() E5AN-H/E5EN-H 53 External Connections • A voltage output (control output 1, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured temperature values as a result of leakage current. The voltage output (control output 2, for driving SSR) has basic insulation provided for the internal circuit Note: Wire all voltage input terminals correctly. The Controller may fail if voltage input terminals are wired incorrectly. Output Unit Control outputs 1, 2 Relay Outputs 250 VAC, 5 A (resistive load) SSR Outputs 75 to 250 VAC, 1A (resistive load) Models with Position- proportional Control 250 VAC, 1 A (including inrush current) Potentiometer RDB RDA SG SDB SDA 4 to 20 mA DC (Load: 600 Ω max.) 4 to 20 mA DC 1 2 3 4 5 6 7 8 9 10 21 22 23 24 25 26 27 28 29 30 21 22 23 24 25 26 27 28 29 30 21 22 23 24 25 26 27 28 29 30 11 12 13 14 15 16 17 18 19 20 EV4 EV3 Transfer output Remote SP input DO NOT USE • 100 to 240 VAC • 24 VAC/VDC (no polarity) Input power supply Auxiliary output 2 Control output 1 B V mA Control output 2 CT2 CT1 EV1 EV2 CT2 DO NOT USE DO NOT USE DO NOT USE B A C W O DO NOT USE DO NOT USE DO NOT USE DO NOT USE Auxiliary output 1 Event Inputs EV1 EV2 Event Inputs Communications B ( +) A ( −) DO NOT USE B ( +) A ( −) 11 12 13 21 22 E53-EN03 RS-485 11 12 13 21 22 E53-EN01 RS-232C SD RD SG DO NOT USE DO NOT USE 11 12 13 21 22 E53-AKB 11 12 13 21 22 E53-EN02 RS-422 Control outputs 1, 2 Relay output SPST-NO, 250 VAC, 3 A (resistive load) Auxiliary outputs 1, 2 Relay output SPDT, 250 VAC, 3 A (resistive load) Auxiliary output 3 A heater burnout alarm, SSR failure, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned. Auxiliary output 3 14 15 16 Option Units Controllers |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |