| 전자부품 데이터시트 검색엔진 |
|
E5CN-R2ML-500 데이터시트(PDF) 60 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CN-R2ML-500 데이터시트(HTML) 60 Page - Omron Electronics LLC |
|
60 / 72 page ![]() E5 @N/E5@N-H 60 M M M M M M M psel cwf u-no 1 bps 9.6 len 7 sbit 2 prty even sdwt 20 Starting in manual mode. M M M M M M pmov 0 oapt 0 pmsk on prlp 0 icpt 1 wtpt off pfpt off M 25 M M M M M M M M M M ST (Self-tuning) M M M M in-t 5 in-h 100 in-l dp d-u sl-h 1300 sl-l -200 cntl onof s-hc stnd st on ptrn off cp 20 c-cp 20 orev or-r 0 0 c M M M l.adj cmwt off at off M M M M M M ct1 0.0 0.0 0.0 hb1 0.0 hb2 0.0 M M 50.0 50.0 M M oc1 50.0 oc2 50.0 M M M sp-0 0 sp-1 0 sp-2 0 sp-3 0 M M M M M M M M M M M M M M M M of-r 50.0 soak 1 c-sc 1.00 d 40 p 8.0 i 233 c-db 0.0 hys 1.0 chys 1.0 ol-l -5.0 wt-b off mv-s 0.0 mv-e 0.0 ol-h 105.0 M M M ins 0.0 insh 0.0 insl 0.0 sprt off sqrp 0.0 M M M a-m 25 25 0 M M M M M M M sp-m 0 ct1 0.0 ct2 0.0 lcr1 0.0 lcr2 0.0 prst rset sktr 0 M m-sp 0 r-s run M M M M M M M M M M M M c-o 0.0 al-1 0 al1h 0 al1l 0 al-2 0 al2h 0 al2l 0 al-3 0 al3l 0 al3h 0 o 0.0 M orl 0.0 M ct2 lcr1 hs1 lcr2 hs2 0.0 0.0 alh1 0.2 M alt1 2 M Power ON Starting in automatic mode. Manual Control Level PID Control only PV/MV Press the O Key less than 1 s. Press the O Key less than 1 s. Operation Level Adjustment Level Adjustment Level Display Displayed only once when entering adjustment level. AT Execute/Cancel Communications Writing Heater Current 1 Value Monitor Heater Burnout Detection 1 Heater Overcurrent Detection 1 Heater Current 2 Value Monitor Heater Burnout Detection 2 Heater Overcurrent Detection 2 Leakage Current 1 Monitor Leakage Current 2 Monitor HS Alarm 1 HS Alarm 2 C SP 0 SP 1 C C SP 2 SP used by multi-SP SP 3 C C C C C C C C Temperature Input Shift 1-point shift 2-point shift Set either of these parameters. Upper Limit Temperature Input Shift Value Lower Limit Temperature Input Shift Value Proportional Band Integral Time PID settings Derivative Time Cooling Coefficient Heating/cooling Dead Band Manual Reset Value Clear the offset during stabilization of P or PD control. Hysteresis (Heating) Hysteresis (Cooling) Hysteresis settings C Soak Time Wait Band MV at Stop MV at PV Error C SP Ramp Set Value MV Upper Limit MV Lower Limit MV Change Rate Limit Extraction of Square Root Low-cut Point C Process Value Added when Additional PV display is ON. C Process Value/ Set Point C C C Auto/Manual Switch PID control only. Added when auto/manual select addition is ON. Multi-SP Set Point Setting Set Point During SP Ramp Heater Current 1 Value Monitor Heater Current 2 Value Monitor Leakage Current 1 Monitor Leakage Current 2 Monitor Program Start Soak Time Remain Press the O and M Keys for at least 3 s. Protect Level Press the O and M Keys for at least 1 s. Press the O Key less than 1 s. Communications Setting Level Note: The time taken to move to the protect level can be adjusted by changing the "Move to protect level time" setting. Note: Displayed only for models with communications. Changes are effective after cycling power or after a software reset. Move to Protect Level: Displayed only when a password is set. Restricts moving to protect level. Operation/Adjustment Protect: Restricts displaying and modifying menus in operation, adjustment, and manual control levels. Initial Setting/ Communications Protect: This protect level restricts movement to the initial setting, communications setting, and advanced function setting levels. Setting Change Protect: Protects changes to setups by operating the front panel keys. Password to Move to Protect Level: Password setting PF Key Protect Restricts PF key operation (E5AN/E5EN only) Parameter Mask Enable: Displayed only when a parameter mask is set. Protocol Setting: Switches between CompoWay/F (SYSWAY) and Modbus. Communications Unit No. Communications Baud Rate CompoWay/F (SYSWAY) only Communications Data Length Communications Stop Bits Communications Parity Send Data Wait Time C RUN/STOP Alarm Value 1 Alarm Value Upper Limit 1 Alarm Value Lower Limit 1 C C C C Alarm Value 2 Alarm Value Upper Limit 2 Alarm Value Lower Limit 2 Alarm Value 3 C C C Alarm Value Upper Limit 3 Alarm Value Lower Limit 3 MV Monitor (Heating) MV Monitor (Cooling) Press the O Key for at least 1 s. Press the O Key less than 1 s. Initial Setting Level Input Type Scaling Upper Limit Scaling Lower Limit Decimal Point For input type of analog C C Temperature Unit °C, °F For input type of temperature SP Upper Limit SP Lower Limit Limit the set point PID ON/OFF Standard or Heating/Cooling For input type of temperature, standard control, or PID Program Pattern When assigning PID or control output to ON/OFF output Control Period (Heating) Control Period (Cooling) Set the ON/OFF output cycle. Direct/Reverse Operation C Alarm 1 Type Alarm 1 Hysteresis Press the O Key for at least 3 s. Other than the Auto/Manual Switch display PF Key ✽2 Press the PF Key for at least 1 s. ✽1 PF Key ✽2 Press the O Key or the PF Key for at least 1 s. ✽1 ✽1. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN/E5EN). ✽2. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN/E5EN). Press the O Key for at least 3 s. Parameters Basic Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156). |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |