Back Button AFE032 Datasheet HTML 14Page - Texas Instruments AFE032 Datasheet HTML 15Page - Texas Instruments AFE032 Datasheet HTML 16Page - Texas Instruments AFE032 Datasheet HTML 17Page - Texas Instruments AFE032 Datasheet HTML 18Page - Texas Instruments AFE032 Datasheet HTML 19Page - Texas Instruments AFE032 Datasheet HTML 20Page - Texas Instruments AFE032 Datasheet HTML 21Page - Texas Instruments AFE032 Datasheet HTML 22Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 77 page
background image
C
=
IN
1
2
18 k
f
´ p
W
HP
´
´
Inside the Device
Power Amplifier
TSENSE
PA_IN
PA_VS1,
PA_VS2,
PA_VS3
PA_ISET
PA_OUT1,
PA_OUT2
PA_GND1,
PA_GND2,
PA_GND3
Optional
RSET
47 PF
100 nF
PA Supply
CIN
17 k:
AFE032
SBOS669A – AUGUST 2013 – REVISED DECEMBER 2013
www.ti.com
Connecting the PA in a typical power line communication (PLC) application requires few additional components.
Figure 13 shows the typical connections to the PA block.
Figure 13. Typical Connections to the PA
The external capacitor (CIN) introduces a single-pole, high-pass characteristic to the PA transfer function. The CIN
and PA combination has a band-pass response because of the inherent low-pass transfer function from the PA.
The value of the high-pass cutoff frequency is determined by CIN reacting with the input resistance of the PA
circuit, and can be determined by Equation 1:
where:
•
CIN = external input capacitor and
•
fHP = desired high-pass cutoff frequency.
(1)
For example, setting CIN to 3.3 nF results in a high-pass cutoff frequency of 2.9 kHz. The voltage rating for CIN
should be determined to withstand operation up to the PA power-supply voltage.
When the transmitter is not in use, the output can be disabled and placed in a high-impedance state by following
the procedure outlined in the Power Amplifier Enable Sequence section.
Refer to the Initialization Sequence and Power Amplifier Enable Sequence sections for details on the proper
sequence when enabling the power amplifier.
18
Submit Documentation Feedback
Copyright © 2013, Texas Instruments Incorporated
Product Folder Links: AFE032



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com