| 전자부품 데이터시트 검색엔진 |
|
ICS1889 데이터시트(PDF) 14 Page - Integrated Circuit Systems |
|
|
|||||||||||||||||||||||||||||
ICS1889 데이터시트(HTML) 14 Page - Integrated Circuit Systems |
|
14 / 35 page ![]() 14 ICS1889 Extended Control Register (register 16) The Extended Control Register is a 16-bit read write register used to pre-program the ICS1889. At power-up and reset, this register will be loaded to the default values specified. It may subsequently be read or written. If written, the result is bit dependent as discussed below. Command Register Override (bit 15) If set to a logic one, this bit allows a subsequent write to the Status Register (register 1) and the PHY identifier registers 2 and 3. The contents of registers 2 and 3 may be set to any value. The Status Register may have certain specified bits set or reset. The first write to registers 1, 2 or 3 after this bit is set will reset it preventing subsequent writes from having any effect. Reserved (bit 14) This bit is reserved for ICS use. It must always be written with a logic zero. The value of this bit when read is unspecified and may be a logic zero or one. Reserved (bit 13) This bit is reserved for ICS use. It must always be written with a logic zero. The value of this bit, when read, is unspecified and may be a logic zero or one. Extended Control Register (register 16) BIT Definition When bit = 0 When bit = 1 Access Default 15 Command Register Override Don’t allow write Allow write RW 0 14 Reserved for ICS Write logic zero. Read unspecified. RW/0 — 13 Reserved for ICS Write logic zero. Read unspecified. RW/0 — 12 Reserved for ICS Write logic zero. Read unspecified. RW/0 — 11 Reserved for ICS Write logic zero. Read unspecified. RW/0 — 10 PHY address - S4 CW P4RD 9 PHY address - S3 MII management CW P3TD 8 PHY address - S2 Register address code CW P2LI 7 PHY address - S1 0 - 31 Read Only CW P1CL 6 PHY address - S0 CW P0FD 5 Reserved for ICS Write logic zero. Read unspecified. RW/0 — 4 Far End Fault Disabled Enabled RW 1 3 Transmit Far End Fault No fault transmitted Fault transmitted RW 0 2 Invalid Error Code Test Disabled Enabled RW 0 1 Reserved for ICS Write logic zero. Read unspecified. RW/0 — 0 Reserved for ICS Write logic zero. Read unspecified. RW/0 — Reserved (bit 12) This bit is reserved for ICS use. It must always be written with a logic zero. The value of this bit when read is unspecified and may be a logic zero or one. Reserved (bit 11) This bit is reserved for ICS use. It must always be written with a logic zero. The value of this bit when read is unspecified and may be a logic zero or one. PHY Address (Bits 10 through 6) These 5 bits are used to indicate the address of the ICS1889 on the management port of the MII (any number in the range 0 - 31). A read returns the address. Extra care should be taken if a command override write is performed on these bits, as a change in the PHY address must be accounted for by the device reading and writing to the MII Management interface. Reserved (bit 5) This bit is reserved for ICS use. It must always be written with a logic zero. The value of this bit when read is unspecified and may be a logic zero or one. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |