28 / 38 page ![]() ADC AN4092 28/38 Doc ID 023080 Rev 2 Equation 9 However the last constraint can’t be always fulfilled. For example when the time constant Rf(Cf+Cp) has to be big in order to filter out very low frequencies. In this case it is preferable to reduce the resistor Rf (as long as the current limitation constraint is kept) and increase Cf: it results in a very small drop due to the charge sharing and eventually a small or negligible error. EXAMPLE 1 Let’s assume that: ● Vamax = 12V ● Rs = 100Ohm ● f0 = 100KHz Using the Equation 1: Let’s choose Rf = 2.2KOhm. Then, from the Equation 3: Let’s choose Cf = 680pF. Then, from the Equation 4: Clocking the ADC at its maximum frequency (16MHz): τ 1 τ 2 T s «« R f 12 5.5 – 310 3 – ⋅ --------------------- 100 – 2K Ω ≅ ≥ C f 1 2 π100 10 3 2.2 10 3 ⋅ () ⋅ ---------------------------------------------------------- 723pF = = T s T c 1 200 10 3 ⋅ () ---------------------------- = + 5 μs = |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|