| 전자부품 데이터시트 검색엔진 |
|
LTC1325CSW 데이터시트(PDF) 17 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC1325CSW 데이터시트(HTML) 17 Page - Linear Technology |
|
17 / 24 page ![]() 17 LTC1325 APPLICATIONS INFORMATION (3). Alternatively, β may be calculated from the RT/RTO ratio using equation (4) or from α, using equation (6). As a numerical example, consider the Panasonic ERT-D2FHL103S thermistor which has the following char- acteristics: 1. RT (25°C) = RTO = 10k 2. α = –4.6%/°C at TO = 25°C 3. Ratio R25/R50 = 2.9 Using equation (4) and R25/R50 = 2.9, β = (323 × 298)In (2.9)/(298 – 323) = 4099k. Alternatively, using equation (6) and α = –4.6%/°C, β = –(–0.046)(298)2 = 4085k. Both values of β are close to each other. Substituting β = 4085k into equation (3) gives RL = 10k [4085 – (2 × 298)]/[4085 + (2 × 298)] = 7.45k. The nearest 1% resistor value is 7.5k. Figure 5 shows a plot of VDIV(T) measured at various temperatures for this thermistor with a 7.5k RL. Figure 5. ERT-D2FHL103S Divider T = [2.605 – VDIV(T)]/0.034. The straight line approxima- tion is accurate to within 2 °C over a temperature range of 5 °C to 45°C, assuming 3% β and 10% RTO tolerances. PTC (Positive Temperature Coefficient) Thermistors Positive Temperature Coefficient (PTC) thermistors may be used in battery chargers that do not require accurate temperature measurements. The resistance vs tempera- ture characteristics of PTC exhibits a sharp increase at a selectable switch temperature TS. This sharp change is exploited in chargers which use TCO (Temperature Cutoff) or ∆TCO (Difference between battery and ambient tem- perature). With TCO termination, a voltage divider consist- ing of a PTC and a low temperature coefficient load resistor is connected between REG and GND with the top end of the PTC at REG. The PTC is mounted on the battery to sense its temperature. The divider output is tied to TBAT. When the switch temperature is reached, the PTC resistance increases sharply causing TBAT to fall below HTF. This causes an HTF fault and charging is terminated. To imple- ment ∆TCO termination, the load resistor can, in principle, be replaced by a matching PTC and the divider now responds to differences between battery and ambient temperature. With both TCO and ∆TCO terminations, the position of the battery temperature PTC can be swapped with the load resistor or ambient temperature PTC. In both cases, an LTF fault terminates charge when the trip point is reached. Note that in practice, matched PTCs are not readily available and for ∆TCO termination, NTC ther- mistors are recommended. HARDWARE DESIGN PROCEDURE This section discusses the considerations in selecting each component of a simple battery charger (see Figures 3 and 4). Further applications assistance is provided in Application Note 64, using the LTC1325 Battery Manage- ment IC. 1. RSENSE: There are three factors in selecting RSENSE: a. LTC1325 VREF and Duty Ratio Settings b. Sense Resistor Dissipation c. ILOAD(RSENSE) < – 450mV for Gas Gauge Linearity TEMPERATURE ( °C) –60 – 0.5 0 1.0 1.5 2.0 4.5 3.0 –20 20 40 LTC1325 • F05 0.5 3.5 4.0 2.5 –40 0 60 80 ACTUAL IDEAL There are two methods of calculating battery or ambient temperature from ADC readings of the TBAT or TAMB channels. The first method is to store the VDIV(T) vs T curve as a lookup table. The second method is to use a straight line approximation. The equation of this line may be calculated from the slope dVDIV/dT at TO [see equation (7)] and assuming that the line passes through the point [TO, VDIV(TO)] on the curve. For the ERT-D2FHL103S, the slope is minus 34mV/ °C and the equation of the line is |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |