29 / 41 page ![]() Application Hints (Continued) 1.6 User Mode and Test Mode An instruction may be issued to the ADC to put it into test mode. Test mode is used by the manufacturer to verify complete functionality of the device. During test mode CH0–CH7 become active outputs. If the device is inadvert- ently put into the test mode with CS continuously low, the serial communications may be desynchronized. Synchroni- zation may be regained by cycling the power supply voltage to the device. Cycling the power supply voltage will also set the device into user mode. If CS is used in the serial inter- face, the ADC may be queried to see what mode it is in. This is done by issuing a “read STATUS register” instruction to the ADC. When bit 9 of the status register is high, the ADC is in test mode; when bit 9 is low the ADC, is in user mode. As an alternative to cycling the power supply, an instruction se- quence may be used to return the device to user mode. This instruction sequence must be issued to the ADC using CS. The following table lists the instructions required to return the device to user mode: Instruction DI Data DI0 DI1 DI2 DI3 DI4 DI5 DI6 DI7 TEST MODE H X X X H H H H Reset Test Mode Instructions LLLL H H H L LLLL H L H L LLLL H L H H USER MODE LLLL H H H H Power Up LLLL H L H L Set DO with H or without or L L L H H L H Sign L Set H H Acquisition or or L L H H H L Time L L Start HHHH HH H a orororor L or or or Conversion LLLL LL L X = Don’t Care After returning to user mode with the user mode instruction the power up, data with or without sign, and acquisition time instructions need to be resent to ensure that the ADC is in the required state before a conversion is started. 1.7 Reading the Data Without Starting a Conversion The data from a particular conversion may be accessed without starting a new conversion by ensuring that the CONV line is taken high during the I/O sequence. See the Read Data timing diagrams. Table 6 describes the operation of the CONV pin. 2.0 DESCRIPTION OF THE ANALOG MULTIPLEXER For the ADC12038, the analog input multiplexer can be configured with 4 differential channels or 8 single ended channels with the COM input as the zero reference or any combination thereof (see Figure 9). The difference between the voltages on the V REF + and V REF − pins determines the input voltage span (V REF). The analog input voltage range is 0toV A +. Negative digital output codes result when V IN − > V IN +. The actual voltage at V IN − or V IN + cannot go below AGND. 01135437 FIGURE 8. Changing the ADC’s Conversion Configuration 4 Differential Channels 01135438 8 Single-Ended Channels with COM as Zero Reference 01135439 FIGURE 9. www.national.com 29 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |