Back Button LP8501TMX/NOPB Datasheet HTML 39Page - Texas Instruments LP8501TMX/NOPB Datasheet HTML 40Page - Texas Instruments LP8501TMX/NOPB Datasheet HTML 41Page - Texas Instruments LP8501TMX/NOPB Datasheet HTML 42Page - Texas Instruments LP8501TMX/NOPB Datasheet HTML 43Page - Texas Instruments LP8501TMX/NOPB Datasheet HTML 44Page - Texas Instruments LP8501TMX/NOPB Datasheet HTML 45Page - Texas Instruments LP8501TMX/NOPB Datasheet HTML 46Page - Texas Instruments LP8501TMX/NOPB Datasheet HTML 47Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 43 / 51 page
background image
LP8501
www.ti.com
SNVS548D – SEPTEMBER 2008 – REVISED AUGUST 2013
–
01 = 300 mV
–
10 = 200 mV
–
11 = 100 mV
–
Note: Values above are typical and should not be used as product specification.
–
Note: Writing to THRESHOLD [7:6] bits by the user overrides factory settings. Factory settings are not
user accessible.
–
76 — Bit [5] — RESERVED
–
This bit is reserved for future use. When writing to register 76h, this bit should be written '0'.
–
76 — Bits [4:3] — TIMER
–
Automatic mode change from 1.5x to 1x is attempted at the interval specified with these bits. After the
specified interval time mode change to 1x is allowed if there is enough voltage over the LED drivers to
ensure proper operation. If FORCE_1x is set to '1' after the specified interval time 1x mode is always
tested.
–
00 = 5 ms
–
01 = 10 ms
–
10 = 50 ms
–
11 = infinite. The charge pump switches gain from 1x mode to 1.5x mode only. The gain reset back to
1x is enabled under certain conditions, for example in the powersave mode.
–
76 — Bit [2] — FORCE_1x
–
Activates forced mode change. In forced mode charge pump mode change from 1.5x to 1x is
attempted at the interval specified with the TIMER bits.
–
1 = forced mode changes enabled
–
0 = forced mode changes disabled
Copyright © 2008–2013, Texas Instruments Incorporated
Submit Documentation Feedback
43
Product Folder Links: LP8501



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com