29 / 57 page ![]() SMBus Fan Control with 1°C Accurate Temperature Monitoring Datasheet SMSC EMC2101 29 Revision 2.54 (06-16-09) DATASHEET 5.7 Fault Queue The EMC2101 supports a Fault Queue feature to reduce interrupts caused by spurious temperature readings. This feature, (see Section 6.5), will not trigger an interrupt until the device has measured three consecutive out-of-limit HIGH, LOW, or T_CRIT temperature readings. Figure 5.8 shows an example of this behavior. The Fault Queue only applies to the External Diode channels. Figure 5.8 Example Fault Queue Response TLIMIT Temp Readings n n+1 n+2 n+3 n+4 n+5 n+6 n+7 n+8 2 consecutive errors 3 consecutive errors Status Register - ETDS high |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|