| 전자부품 데이터시트 검색엔진 |
|
EMC2101-R-ACZL-TR 데이터시트(PDF) 42 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
EMC2101-R-ACZL-TR 데이터시트(HTML) 42 Page - SMSC Corporation |
|
42 / 57 page ![]() SMBus Fan Control with 1°C Accurate Temperature Monitoring Datasheet Revision 2.54 (06-16-09) 42 SMSC EMC2101 DATASHEET Bit 1-0 - TACH_M[1:0] - Determines the basic operation of the tachometer input as shown in Table 6.19. Note 6.2 When the PWM base clock is set at 360kHz mode 00b is used regardless of the setting of the TACH_M[1:0] bits. 6.17 Fan Spin Up Configuration Register The Fan Spin Up Configuration register controls the spin-up behavior of the device. The Fan driver enters its spin-up routine any time it transitions from a minimum fan setting (00h) to a higher fan setting (but does not invoke the spin-up routine upon power up). Once the spin-up time has been met, the fan driver is reduced to the programmed setting. Bit 5 - FAST_TACH - Determines whether the Spin-Up routine aborts when the measured TACH is less than the TACH Limit. ‘0’ - The Spin-Up routine uses the duty cycle and spin-up time independently of the TACH reading. ‘1’ (default) - The Spin-Up routine will abort when the TACH measurement is less than the TACH Limit or the programmed Spin-Up time is met, whichever is less. In this case, the SPIN_DRIVE[1:0] bits are ignored and the drive will always be at 100%. APPLICATION NOTE: This bit will be ignored if the ALT_TCH bit in the Configuration Register (see Section 6.5) is set to ‘0’. APPLICATION NOTE: If the SPIN_TIME[2:0] bits are set at 000b, then the Spin-Up Routine is bypassed regardless of the status of this bit. Bit 4 - 3 SPIN_DRIVE[1:0] - Determines the setting of the drive circuit during the Spin-Up routine according to Table 6.21. Table 6.19 TACH Modes TACH_M[1] TACH_M[0] TACH MODE 00 False readings when under minimum detectable RPM (TACH Limit). (Default condition - See Note 6.2) 0 1 FFFFh reading when under minimum detectable RPM. 10 11 Table 6.20 Fan Spin Up Configuration Register ADDR. R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 4Bh R/W Fan Spin Up Config -- FAST_ TACH SPIN_DRIVE[1:0] SPIN_TIME[2:0] 3Fh |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |