33 / 57 page ![]() SMBus Fan Control with 1°C Accurate Temperature Monitoring Datasheet SMSC EMC2101 33 Revision 2.54 (06-16-09) DATASHEET 6.3 Temperature Data Registers As shown in Table 6.2, the internal temperature monitor is stored as an 8-bit value while the external temperature is stored as an 11-bit value. Please note that the internal temperature monitor is limited to the operating temperature limits of the part resulting in a guaranteed range of 0ºC to 85ºC. 6.4 Status Register The Status Register is a read only register and returns the operational status of the part. If the ALERT / TACH pin is configured as an ALERT output and any of these bits are set to '1' (except the BUSY bit and the FAULT bit), then the ALERT / TACH pin is asserted low (if interrupts are not masked (see Section 6.5). Reading from the Status Register will cause the MASK bit to be set if any bit (other than BUSY and FAULT) have been set. Each bit is automatically cleared when the error condition has been removed, however the internal error condition flags may still be set. The ARA command must be used to clear the ALERT / TACH pin if there are no bits set in the Status Register. In addition, reading from the Status Register will clear all bits. If the error condition persists, then the bits will be reset at the end of the next conversion. When the device is configured in Comparison Mode (see Section 6.23), reading the Status Register will not clear any active status bits (except EEPROM and FAULT). These bits are automatically cleared when the error condition is removed. Bit 7 - Busy - indicates that the ADC is converting - does not trigger an interrupt. Bit 6 - INT_HIGH - Internal temperature has met or exceeded the high limit. Bit 5 - EEPROM - Indicates that the EEPROM could not be found when the device powers up in the Auto-Program Mode (see Section 5.1). This bit only applies to the EMC2102-R. It will always read ‘0’ for the EMC2101 device. Bit 4 - EXT_HIGH - External Diode temperature has exceeded the high limit. Table 6.2 Temperature Data Registers ADDR. R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 00h R Internal Temperature Sign 64 32 16 8 4 2 1 00h 01h R External Diode Temperature High Byte Sign 64 32 16 8 4 2 1 00h 10h R External Diode Temperature Low Byte 0.5 0.25 0.125 - - - - - 00h Table 6.3 Status Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 02h R Status BUSY INT_ HIGH EEPROM EXT_ HIGH EXT_ LOW FAULT TCRIT TACH 00h |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |