| 전자부품 데이터시트 검색엔진 |
|
PC97307 데이터시트(PDF) 152 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC97307 데이터시트(HTML) 152 Page - National Semiconductor (TI) |
|
152 / 218 page ![]() 152 UART1 and UART2 (with IR) (Logical Devices 5 and 6) www.national.com TABLE 7-12. Bits Cleared On Fallback . FIGURE 7-19. LBGD(L) Register Bitmap . FIGURE 7-20. LBGD(H) Register Bitmap 7.11.13 Link Control Register (LCR) and Bank Select Register (BSR), Bank 1, Offset 03h These registers are the same as the registers at offset 03h in bank 0. 7.12 BANK 2 – EXTENDED CONTROL AND STATUS REGISTERS Bank 2 contains two alternate Baud Generator Divisor ports and the Extended Control Registers (EXCR1 and EXCR2). Register UART Mode & LOCK bit before Fallback Extended Mode LOCK = x Non-Extended Mode LOCK = 0 Non-Extended Mode LOCK = 1 MCR 2 to 7 none none EXCR1 0, 5 and 7 5 and 7 none EXCR2 0 to 5 0 to 5 none IRCR1 2 and 3 none none 76543210 Reset Required Low Byte port (LBGD(L)) Bank 1, Least Significant Byte Legacy Baud Generator Divisor of Baud Generator Offset 00h 76543210 Reset Required High Byte port (LBGD(H)) Bank 1, Most Significant Byte Legacy Baud Generator Divisor of Baud Generator Offset 01h TABLE 7-13. Bank 2 Register Set 7.12.1 Baud Generator Divisor Ports, LSB (BGD(L)) and MSB (BGD(H)), Bank 2, Offsets 00h and 01h These ports perform the same function as the Legacy Baud Divisor Ports in Bank 1 and are accessed identically to them, but do not change the operation mode of the module when ac- cessed. Refer to Section 7.11.12 on page 151 for more detail. Use these ports to set the baud rate when operating in Extend- ed mode to avoid fallback to a Non-Extended operation mode, i.e., 16550 compatible.When programming the baud rate, writ- ing to BGDH causes the baud rate to change immediately. FIGURE 7-21. BGD(L) Register Bitmap FIGURE 7-22. BGD(H) Register Bitmap Offset Register Name Description 00h BGD(L) Baud Generator Divisor Port (Low byte) 01h BGD(H) Baud Generator Divisor Port (High byte) 02h EXCR1 Extended Control Register 1 03h LCR/BSR Link Control/ Bank Select Register 04h EXCR2 Extended Control Register 2 05h Reserved 06h TXFLV TX_FIFO Level 07h RXFLV RX_FIFO Level 76543210 Reset Required x x x x x x x x Low Byte Port (BGD(L)) Bank 2, Least Significant Byte Baud Generator Divisor of Baud Generator Offset 00h 76543210 Reset Required x x x x x x x x High Byte Port (BGD(H)) Bank 2, Most Significant Byte of Baud Generator Baud Generator Divisor Offset 01h |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |