Back Button L9659 Datasheet HTML 41Page - STMicroelectronics L9659 Datasheet HTML 42Page - STMicroelectronics L9659 Datasheet HTML 43Page - STMicroelectronics L9659 Datasheet HTML 44Page - STMicroelectronics L9659 Datasheet HTML 45Page - STMicroelectronics L9659 Datasheet HTML 46Page - STMicroelectronics L9659 Datasheet HTML 47Page - STMicroelectronics L9659 Datasheet HTML 48Page - STMicroelectronics L9659 Datasheet HTML 49Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 45 / 51 page
background image
L9659
Functional description
Doc ID 022048 Rev 2
45/51
Monitor mode 2
Monitor mode main information:
●
Current limit measurement of channels
The SPI message definition for MOSI commands and MISO responses in Monitor Mode 2
are defined below.
Bits [D9:D7].
Used when sending the MOSI command to select the channel to be
measured. The MISO response will echo the MOSI command.
MSB
LSB
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
MOSI Command for Monitor Mode 2
1
1
P
CLR
0
1
Current
Measurement
Channel Select
0
0
0
0
0
0
0
MISO Response for Monitor Mode 2
1
1
P
0
0
1
Current
Measurement
Channel
Current Measurement Data
Table 28.
MOSI monitor mode 2 Bit definition
Bit
MOSI command
MISO response
State
Description
D15
1
Mode bits
See above for state
D14
1
Mode bits
See above for state
D13
Odd parity – Includes all 16 bits
Odd Parity – Includes all 16 bits
D12
0
Keep timer measurements
See above for state
1
Clear “current measurement time” stored
on the register of channel selected by
D9:D7
See above for state
D11
0
Monitor mode selection bits
See above for state
D10
1
Monitor mode selection bits
See above for state
D9
Channel selected for current
measurement
See Table 29
Internal Stored channel selections bits
D8
D7
D6:D0
0
-
Current measurement of selected
channel
Table 29.
Current measurement channel selections
Channel
Bit D9
Bit D08
Bit D07
0
0
0
0
1
0
0
1
2
0
1
0
3
0
1
1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com