Back Button MS1003SH Datasheet HTML 33Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 34Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 35Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 36Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 37Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 38Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 39Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 40Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 41Page - Shindengen Electric Mfg.Co.Ltd  
Zoom Inzoom in Zoom Outzoom out
 40 / 41 page
background image
MS1003SH・MS1004SH
Application Note Ver.2.2
SHINDENGEN ELECTRIC MFG. CO. , LTD
40/41
(8) Checking operating points
When checking the operating points, use the design values corrected in Section 6.2 (7)-3).
Work out the operating points of the example power supply in accordance with Section 5.4.
The following table gives the results of calculations based on an input voltage of DC 120 V:
(1)
Trough skip start power
9.33[W]
(2)
Operating frequency at trough skip start
133.3[kHz]
(3)
Trough skip end power
Trough skip end power 1 from Formula 25 of [Condition 1]
.................................................................................... 16.23[W]
As DC 120 V = VDC < VDC (clamp) = 129.4 V;
Trough skip end power 2 from Formula 30 of [Condition 2]-1)
.................................................................................... 26.77[W]
Trough skip end power 1 < Trough skip end power 2
Trough skip end power 1 is used.
16.23[W]
(4)
Operating frequency at trough skip end
Calculated from Formulas 22 and 23 for trough skip end
power 1.
60.74[kHz]
(5)
Auto burst start power
0.62[W]
(6)
Operating frequency immediately before auto burst start
151.86[kHz]
(7)
Auto burst end power
1.03[W]
(8)
Operating frequency immediately after auto burst end
141.87[kHz]
(9)
Droop point power
Calculated from Formula 30 as DC 120 V = VDC < VDC
(clamp) = 129.4 V.
31.8[W]
(10)
Operating frequency at droop point
54.3[kHz]
The chart below shows a model of the operating frequency characteristics relative to output power
indicating each operating point. Check the operating points (1) to (10).
Output power [W]
(6)
(5)(7)
(1)
(3)
(9)
(8)
(2)
(4)
(10)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com