8 / 41 page ![]() MS1003SH・MS1004SH Application Note Ver.2.2 SHINDENGEN ELECTRIC MFG. CO. , LTD 8/41 3.1.2 Soft start At startup, the OCL level changes in four stages. Current flowing to the main switch also increases in stages. The envelope curves of the current to the main switch are shaped in four steps to avoid abrupt switch startups. The soft start time depends on the Tss1 to Tss3 settings. The time settings are determined by the IC. 3.1.3 Bias assist Soon after oscillation begins during startup, the voltage drops, and the oscillation may halt. To prevent this and ensure proper startup, the bias assist function supplies energy to the Vcc pin. Shown below is a schematic diagram of Vcc startup incorporating the bias assist function. Steady-state operation Normal OCL level Assist function activates. If the voltage drops below the oscillation stop voltage, oscillation halts, and the startup circuit must restart. The voltage remains above the oscillation stop voltage to ensure that oscillation does not halt. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|