| 전자부품 데이터시트 검색엔진 |
|
MFC2000 데이터시트(PDF) 153 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
MFC2000 데이터시트(HTML) 153 Page - List of Unclassifed Manufacturers |
|
153 / 426 page ![]() Hardware Description MFC 2000 Multifunctional Peripheral Controller 2000 100723A Conexant 7-5 Bit 15-8 Shift Enable[7:0] These bits are used to shift scanner controller signals by ½ ihsclk. By default, all scanner controller signals are synchronized to the rising edge of ihsclk. By setting this bit, the corresponding scanner controller signal will be shifted by ½ ihsclk, i.e., it will be synchronized to the falling edge of ihsclk. ShiftEnb[7]: to shift ‘sample’ signal ShiftEnb[6:1]: to shift ‘scctrl[6:1]’ signals ShiftEnb[0]: to shift ‘clamp’ signal Bit 2 VSC on EV bus When this bit is set, the “EV_VD[5:0]” bus will be turned into output with the following signals on the bus: EV_VD[5:0] Output signals 5 ScanIAConfig[5] as GPO 4 ScanIAConfig[4] as GPO 3 sample/clk2d 2 clk1/clk2c 1 clk1/clk2b 0 clamp Bit 1 ihsclk period 0: ihsclk period = sysclk period 1: ihsclk period = sysclk period/2) This bit determines the period of ihsclk (the primary clock of VSC). Bit 0 VSC Mode 0: scanner 1: video This mode will determine the source of data. Name/Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Default Scan Cycle (ScanCycle) $01FF8891 (Not Used) (Not Used) (Not Used) MSINT IRQ location Rst. Value xxx11111h Read Value 1Fh Name/Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Scan Cycle (ScanCycle) $01FF8890 (Not Used) (Not Used) (Not Used) Scan Cycle (n) MSINTs per Scan Cycle = (n+1) Rst. Value xxx00000b Read Value 00h Bits 12-8 MSINT IRQ location The value written here is double-bufferred. At the beginning of a scan cycle, the value will be transferred into another buffer which is compared to a scan cycle counter. If the value in the buffer matches the value in the counter, then an interrupt will be generated (if it is enabled) at the beginning of the count. Bits 4-0 Scan Cycle (n, n = 0-31; MSINTs per scan cycle = n+1) The value written here is double-buffered. At the beginning of a scan cycle, the value will be transferred into another buffer. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |