Back Button CMV2000 Datasheet HTML 23Page - ams AG CMV2000 Datasheet HTML 24Page - ams AG CMV2000 Datasheet HTML 25Page - ams AG CMV2000 Datasheet HTML 26Page - ams AG CMV2000 Datasheet HTML 27Page - ams AG CMV2000 Datasheet HTML 28Page - ams AG CMV2000 Datasheet HTML 29Page - ams AG CMV2000 Datasheet HTML 30Page - ams AG CMV2000 Datasheet HTML 31Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 27 / 64 page
background image
Reference: CMV2000-datasheet-v3.8
CMV2000 v3 Datasheet
Page 26 of 63
© 2015 CMOSIS bvba
4.5.1 DVAL, LVAL, FVAL
The first three bits of the control word must be used to identify valid data and the read-out status.
Figure 30 shows the timing of the DVAL, LVAL and FVAL bits of the control channel with an example of the read-out of
a frame of 3 rows (default is 1088 rows). This example uses the default mode of 16 outputs in 10 bit mode.
IDLE
OH
128
OH
128
OH
128
DATA_OUT
DVAL
LVAL
FVAL
FIGURE 30: DVAL, LVAL AND FVAL TIMING IN 16 CHANNEL OUTPUT MODE
When only 8 outputs are used, the line read-out time is 2x longer. The control channel takes this into account and the
timing in this mode are shown in Figure 31 and Figure 32. The timing extrapolates identically for 4 and 2 outputs.
IDLE
OH
128
OH
128
OH
128
DATA_OUT
DVAL
LVAL
FVAL
OH
128
OH
128
OH
128
FIGURE 31: DVAL, LVAL AND FVAL TIMING IN 8 CHANNEL OUTPUT MODE
OH
128
OH
128
OH
128
DATA_OUT
DVAL
LVAL
FVAL
OH
128
OH
128
OH
128
Exposure 1
Read-out 1
FOT
Frames
cycle
Exposure 2
Read-out 2
FOT
DVAL [0]
LVAL [1]
FVAL [2]
SLOT [3]
ROW [4]
FOT [5]
INTE1 [6]
INTE2 [7]
10 0000 0000
Data
CTRL_OUT
Data
Data
Data
Data
Data
Data
Data
Data
Data
10 000x xxxx
10 1100 0000 10 0010 0000
10 000x xxxx
Training Pattern
DATA_OUT
Data
Training
Data
Training Pattern
10 1100 0000
10 0010 0000
10 0000 0000
10 110x xxxx
Read-out 1
Exposure 2
Frames
cycle
SLOT
ROW
FOT
INTE1
INTE2
10 0001
1000
CTRL_OUT
10 0000 0111
10 0000
1110
10 0000 0111
10 0001
1100
10 0000 0111
10 0000
1110
10 0000 0111
10 0001
0011
10 0000 0111
10 1100
1110
10 1100 0111
10 1100 0111
10 bit, 8 outputs, single window of 3 lines
FIGURE 32: DETAILED TIMINGS OF THE CONTROL CHANNEL (8 OUTPUTS, 3 LINES WINDOW)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com