21 / 98 page ![]() M58LT128GST, M58LT128GSB 4 Command Interface 21/98 4.6 Block Erase command The Block Erase command is used to erase a block. It sets all the bits within the selected block to ’1’. All previous data in the block is lost. If the block is protected then the erase operation will abort, the data in the block will not be changed and the Status Register will output the error. Two Bus Write cycles are required to issue the command. 1. The first bus cycle sets up the Block Erase command. 2. The second latches the block address and starts the Program/Erase Controller. If the second bus cycle is not the Block Erase Confirm code, Status Register bits SR4 and SR5 are set and the command is aborted. Once the command is issued the bank enters Read Status Register mode and any read operation within the addressed bank will output the contents of the Status Register. A Read Array command is required to return the bank to Read Array mode. During Block Erase operations the bank containing the block being erased will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command, all other commands will be ignored. The Block Erase operation aborts if Reset, RP, goes to VIL. As data integrity cannot be guaranteed when the Block Erase operation is aborted, the block must be erased again. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being erased. Typical Erase times are given in Table 16: Program/Erase Times and Endurance Cycles. See Appendix C, Figure 22: Block Erase Flowchart and Pseudo Code, for a suggested flowchart for using the Block Erase command. 4.7 Program command The program command is used to program a single Word to the memory array. Two Bus Write cycles are required to issue the Program Command. 1. The first bus cycle sets up the Program command. 2. The second latches the address and data to be programmed and starts the Program/ Erase Controller. Once the programming has started, read operations in the bank being programmed output the Status Register content. During a Program operation, the bank containing the Word being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command, all other commands will be ignored. A Read Array command is required to return the bank to Read Array mode. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being programmed. Typical Program times are given in Table 16: Program/Erase Times and Endurance Cycles. The Program operation aborts if Reset, RP, goes to VIL. As data integrity cannot be guaranteed when the Program operation is aborted, the Word must be reprogrammed. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |