173 / 221 page ![]() 2016-2017 Microchip Technology Inc. DS00002084C-page 173 UPD360 1. The port power switch will be turned off (trip action). 2. The PPC will enter the Error state and assert ALERT. 3. The fault handling circuitry will then determine subsequent actions. Figure 12-1 shows operation of current limits in trip mode with the shaded area representing the USB 2.0 specified VBUS range. Dashed lines indicate the port power switch output will go to zero (e.g., trip) when ILIM is exceeded. Note that operation at all possible values of ILIM are shown in Figure 12-1 for illustrative purposes only; in actual operation only one ILIM can be active at any time. FIGURE 12-1: TRIP CURRENT LIMITING OPERATION 5 4 3 2 1 0.53 1.07 1.6 2.67 3.2 5.25 4.75 IBUS (Amps) Operating Current 0 0 0.96 1.28 1.28 1.07 0.96 0.53 1.6 3.2 2.13 2.67 = ILIM’s 2.13 Power Switch Voltage and Current Output go to Zero when ILIM is Exceeded Trip action (ILIM = 0.53 A) Trip action (ILIM = 3.2 A) ILIM (Amps) |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|