| 전자부품 데이터시트 검색엔진 |
|
ATXMEGA8E5 데이터시트(PDF) 145 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
ATXMEGA8E5 데이터시트(HTML) 145 Page - Microchip Technology |
|
145 / 153 page ![]() 2018 Microchip Technology Inc. Data Sheet Complete DS40002059A-page 145 ATxmega32E5/16E5/8E5 38.2 Rev. A • DAC: AREF on PD0 is not available for the DAC • EDMA: Channel transfer never stops when double buffering is enabled on sub-sequent channels • ADC: Offset correction fails in unsigned mode • ADC: Averaging is failing when channel scan is enabled • ADC: Averaging in single conversion requires multiple conversion triggers • ADC accumulator sign extends the result in unsigned mode averaging • ADC: Free running average mode issue • ADC: Event triggered conversion in averaging mode • AC: Flag can not be cleared if the module is not enabled • USART: Receiver not functional when variable data length and start frame detector are enabled • T/C: Counter does not start when CLKSEL is written • EEPROM write and Flash write operations fails under 2.0V • TWI master or slave remembering data • Temperature Sensor not calibrated Issue: DAC: AREF on PD0 is not available for the DAC The AREF external reference input on pin PD0 is not available for the DAC. Workaround: No workaround. Only AREF on pin PA0 can be used as external reference input for the DAC. Issue: EDMA: Channel transfer never stops when double buffering is enabled on sub-sequent channels When the double buffering is enabled on two channels, the channels which are not set in double buffering mode are never disabled at the end of the transfer. A new transfer can start if the channel is not disabled by software. Workaround: • CHMODE = 00 Enable double buffering on all channels or do not use channels which are not set the double buffering mode. • CHMODE = 01 or 10 Do not use the channel which is not supporting the double buffering mode. Issue: ADC: Offset correction fails in unsigned mode In single ended, unsigned mode, a problem appears in low saturation (zero) when the offset correction is activated. The offset is removed from result and when a negative result appears, the result is not correct. Workaround: No workaround, but avoid using this correction method to cancel V effect. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |