| 전자부품 데이터시트 검색엔진 |
|
MPF5024AMBA0ES 데이터시트(PDF) 49 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPF5024AMBA0ES 데이터시트(HTML) 49 Page - NXP Semiconductors |
|
49 / 93 page ![]() NXP Semiconductors PF5024 Power management integrated circuit (PMIC) for high performance applications PF5024 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2020. All rights reserved. Product data sheet Rev. 1 — 15 April 2020 49 / 93 The default output voltage configuration for Run and Standby modes is loaded from the OTP_VSWx[7:0] registers upon power up. Table 37. SWx output voltage configuration Set point VSWx_RUN[7:0] VSWx_STBY[7:0] VSWxFB (V) 0 00000000 0.40000 1 00000001 0.40625 2 00000010 0.41250 3 00000011 0.41875 . . . . . . 175 10101111 1.49375 176 10110000 1.50000 177 10110001 1.80000 178 to 255 10110010 to 11111111 Reserved DVS operation is available for all voltage settings between 0.4 V to 1.5 V. However, the SWx regulator is not intended to perform DVS transitions to or from the 1.8 V configuration. In the event a voltage change is requested between any of the low voltage settings and 1.8 V, the switching regulator is automatically disabled first and then re- enabled at the selected voltage level to avoid an uncontrolled transition to the new voltage setting. Each regulator is provided with two bits to set its mode of operation. • The SWx_RUN_MODE[1:0] bits allow the user to change the mode of operation of the SWx regulators during the run state. If the regulator was programmed as part of the power up sequence, the SWx_RUN_MODE[1:0] bits are loaded with 0b11 (autoskip) by default. Otherwise it is loaded with 0b00 (disabled). • The SWx_STBY_MODE[1:0] bits allow the user to change the mode of operation of the SWx regulators during the standby state. If the regulator was programmed as part of the power up sequence, the SWx_STBY_MODE[1:0] bits are loaded with 0b11 (autoskip) by default. Otherwise it is loaded with 0b00 (disabled). Table 38. SWx regulator mode configuration SWx_MODE[1:0] Mode of operation 00 OFF 01 PWM mode 10 PFM mode 11 Auto skip mode The SWx_MODE_I interrupt asserts the INTB pin when any of the Type 1 regulators have changed the mode of operation, provided the corresponding interrupt is not masked. To avoid potential detection of an OV/UV fault during SWx ramp up, it is recommended to power up the regulator in PWM or autoskip mode. SWx regulators use 2 bits SWxILIM[1:0], to program the current limit detection. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |