| 전자부품 데이터시트 검색엔진 |
|
MPF5024AMBA0ES 데이터시트(PDF) 57 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPF5024AMBA0ES 데이터시트(HTML) 57 Page - NXP Semiconductors |
|
57 / 93 page ![]() NXP Semiconductors PF5024 Power management integrated circuit (PMIC) for high performance applications PF5024 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2020. All rights reserved. Product data sheet Rev. 1 — 15 April 2020 57 / 93 15.3.1 Electrical characteristics Table 50. VMON electrical characteristics All parameters are specified at TA = –40 °C to 125 °C, unless otherwise noted. Typical values are characterized at VIN = 5.0 V, VxFB = 1.5 V (Type 1 Buck regulator), and TA = 25 °C, unless otherwise noted. Symbol Parameter Min Typ Max Unit IQON Block quiescent current, when block is enabled one block per regulator one block per regulator — 10 13 µA IOFF Block leakage current when disabled — — 500 nA tON_MON Voltage monitor settling time after enabled — — 30 µs VxFBUVHysteresis Power good (UV) hysteresis Voltage difference between UV rising and falling thresholds — 0.5 — % VUV_Tol Undervoltage falling threshold accuracy With respect to target feedback voltage tolerance For type 1 switching regulator when VSWxFB > 0.75 V −2 — 2 % VUV_Tol Under voltage falling threshold accuracy With respect to target feedback voltage For type 1 switching regulator when VSWxFB ≤ 0.75 V −3 — 3 % Power good (UV) debounce time UV_DV = 00 2.5 5.0 7.5 Power good (UV) debounce time UV_DV = 01 10 15 20 Power good (UV) debounce time UV_DV = 10 20 30 40 tUV_DB Power good (UV) debounce time UV_DV = 11 25 40 55 µs VOV_Tol Overvoltage rising threshold accuracy With respect to target feedback voltage tolerance For type 1 switching regulator when VSWxFB > 0.75 V −2 — 2 % VOV_Tol Overvoltage rising threshold With respect to target feedback voltage tolerance For type 1 switching regulator when VSWxFB ≤ 0.75 V −3 — 3 % VxFBOVHysteresis Overvoltage (OV) hysteresis Voltage difference between OV rising and falling thresholds — 0.5 — % Power good (OV) debounce time OV_DV = 00 20 30 40 Power good (OV) debounce time OV_DV = 01 35 50 65 Power good (OV) debounce time OV_DV = 10 55 80 105 tOV_DB Power good (OV) debounce time OV_DV = 11 90 135 160 µs 15.4 Clock management The clock management provides a top-level management control scheme of internal clock and external synchronization intended to be primarily used for the switching regulators. The clock management incorporates various subblocks: • Low power 100 kHz clock • Internal high frequency clock with programmable frequency • Phase Locked Loop (PLL) A digital clock management interface is in charge of supporting interaction among these blocks. The clock management provides clocking signals for the internal state machine, the switching frequencies for the buck converters as well as the multiples of those switching frequencies in order to enable phase shifting for multiple phase operation. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |