| 전자부품 데이터시트 검색엔진 |
|
H7CC-R11WD 데이터시트(PDF) 16 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CC-R11WD 데이터시트(HTML) 16 Page - Omron Electronics LLC |
|
16 / 66 page ![]() 16 H7CC-A @ Counter *7 Note: Not displayed when the H7AN compatibility function is ON. Note: Not displayed when the H7AN compatibility function is ON. * The display shows 5 kHz, but the maximum counting speed is 10 kHz. Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. Note: Displayed for output modes other than D, L, and H. HOLD cannot be set when the output mode is K-2. *7 Set each digit using the individual UP1 to UP4 Keys (DW1 to DW4 Keys). *7 Set each digit using the individual UP1 to UP4 Keys (DW1 to DW4 Keys). * Use UP1+UP3 to move up and DW1+DW3 to move down (1 ms) (20 ms) (30 Hz) (5 kHz) * (0.50 s) (99.99 s) (0.01 s) (0.50 s) (99.99 s) (0.01 s) (99.999) (1.000) (0.001) (0.50 s) (99.99 s) (0.01 s) * * * * * * * * * (OFST) (ABS) Note: Displayed only when the configuration selection mode is set to the 2-stage counter 2cnt and there is a forecast value setting. Note: Displayed only when the configuration selection mode is set to the 2-stage counter 2cnt. * * * * Note: Displayed only when the output mode is bcnt To next page From next page Output time (OTIM) NPN/PNP input mode (IMOD) Prescale value (PSCL) Counting speed (CNTS) Reset input signal width (IFLT) Decimal point position (DP) (No decimal point) (One digit after decimal point) (Two digits after decimal point) (Three digits after decimal point) (PNP input) (NPN input) When using as a 2-stage preset counter One-shot output 2 time (OTM2) One-shot output 1 time (OTM1) (0.01 s) (99.99 s) (Outputs held) Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. When using as a batch counter One-shot output 2 time (OTM2) • Set the counting speed using the UP1 Key (DW1 Key). • Set the Reset input signal width using the UP1 Key (DW1 Key). • Set the decimal point position using the UP1 Key (DW1 Key). • Set each digit using the individual UP1 to UP4 Keys (DW1 to DW4 Keys). • Set each digit using the individual UP1 Key (DW1 Key). • Set the NPN/PNP input mode using the UP1 Key (DW1 Key). ------ -----.- ----.-- ---.--- 0.01 99.99 0.50 30h 1 s 0.001 99.999 1.000 pnp npn 20 s 0.50 hold 0.01 99.99 0.01 0.50 99.99 0.01 99.99 0.50 0.01 99.99 0.50 0.01 99.99 (999999) (1) 999999 1 (999999) (1) 999999 1 ofst abs (999999) (1) 999999 1 From previous page To previous page If the output time is 0.00, hold is displayed. Note:Displayed only when the output mode is C, R, K-1, P, Q, or A. Note:Displayed only when the output mode is C, R, K-1, P, Q, or A. (0.50 s) (99.99 s) (0.01 s) Twin Counter Output 2 output time (OTM2) Output 1 output time (OTM1) (0.50 s) (99.99 s) (0.01 s) • Make the absolute value setting and forecast setting using the UP1 Key (DW1 Key). Absolute value setting/forecast value setting (SETM) • Set each digit using the individual UP1 to UP6 Keys (DW1 to DW6 Keys). • Set each digit using the individual UP1 to UP6 Keys (DW1 to DW6 Keys). • Set each digit using the individual UP1 to UP6 Keys (DW1 to DW6 Keys). Forecast setting upper limit (PL-H) Set value upper limit (SL-H) Batch count upper limit (BL-H) 0.50 otm2 0.50 otm2 hold otm1 0.50 otm2 0.50 otm1 0.50 otim 30hz cnts 999999 sl-h 1 pl-h 999999 bl-h abs setm npn imod 1.000 pscl ------ dp 20m5 iflt |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |