40 / 57 page ![]() 2015-2021 Microchip Technology Inc. DS20005426G-page 40 MCP960X/L0X/RL0X 5.3.3 ALERT CONFIGURATION REGISTERS This device integrates four individually controlled temperature alert outputs. Each output is configured for the corresponding alert output using the Alert Output Configuration registers. The Configuration registers are used to enable each output, select the Alert Function mode as Comparator or Interrupt mode, active-high or active-low output, detect rising or falling temperatures and detect TH or TC Temperature registers. The Comparator mode is useful for thermostat-type applications, such as on/off switches for fan controllers, buzzer or LED indicators. The alert output asserts and deasserts when the temperature exceeds the user-specified limit, and the user-specified hysteresis limit. The Interrupt mode is useful for interrupt driven microcontroller-based systems. The alert outputs are asserted each time the temperature exceeds the user-specified alert limit and hysteresis limits. The microcontroller will have Acknowledged the interrupt signal from the corresponding alert output by clearing the interrupt using bit 7 of the corresponding Configuration register. The Rise/Fall bit (bit 3) and the Monitor TH/TC bit (bit 4) can be used to detect and maintain the thermocouple temperature or the cold-junction temperature to the desired temperature window. TABLE 5-6: ALERT CONFIGURATION REGISTERS Register Register Pointer Alert 1 Configuration 0000 1000 Alert 2 Configuration 0000 1001 Alert 3 Configuration 0000 1010 Alert 4 Configuration 0000 1011 REGISTER 5-11: ALERT 1, 2, 3 AND 4 CONFIGURATION REGISTER R/W-0 U-0 U-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 Interrupt Clear — — Monitor TH/TC Rise/Fall Active-High/Low Comp/Int. Alert Enable bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’ -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bit 7 Interrupt Clear: Interrupt Clear bit 1 = Clears Interrupt flag (forced ‘0’ by device) 0 = Normal state or cleared state bit 6-5 Unimplemented: Read as ‘0’ bit 4 Monitor TH or TC: Temperature Maintain/Detect bit 1 = Alert monitor for TC cold-junction sensor 0 = Alert monitor for TH thermocouple temperature bit 3 Rise/Fall: Alert Temperature Direction bit 1 = Alert limit for falling or cooling temperatures 0 = Alert limit for rising or heating temperatures bit 2 Active-High/Low: Alert State bit 1 = Active-high 0 = Active-low bit 1 Comp./Int.: Alert Mode bit 1 = Interrupt mode: Interrupt clears bit (bit 7) – must be set to deassert the alert output 0 = Comparator mode bit 0 Alert Enable: Alert Output Enable bit 1 = Alert output is enabled 0 = Alert output is disabled |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |