| 전자부품 데이터시트 검색엔진 |
|
STPM066S 데이터시트(PDF) 22 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STPM066S 데이터시트(HTML) 22 Page - STMicroelectronics |
|
22 / 67 page ![]() Figure 11. Watchdog Early, Safe and Late window diagram TSWn = Safe window #1..4 TEFWn = Early Failure window #1..4 TLFWn = Late failure window #1..4 TLFWn_min TSWn_max tim safe trigger area Late Watchdog Failure undefined undefined TEFWn_max Earl Watchdog Failure TSWn_min GAPG1502160942PS 4.2.10 Under-Voltage, Over-Voltage and Power-Good All regulators are monitored and Power-Good, Over-Voltage and Under-Voltage information is provided through SPI. One SPI bit allows to select between two threshold options for each regulator. Over-voltage and Power-Good are checked when the signal is rising, the Under-Voltage is valid when the signal is falling. 4.2.11 Temperature control and VBATx voltage through internal ADC In order to provide an advanced on-chip temperature control, power outputs are grouped in 7 clusters with dedicated thermal sensors. The sensors are suitably located on the device (see Section 4.2.5 ADC). In case the temperature of a cluster reaches the thermal shutdown threshold, the event is written in the register, the fault pin is activated, and the single regulator is switched off (all other outputs remain active). In particular, what is described below takes place. Thermal Cluster TH1: in case the temperature of TH1 reaches the thermal shutdown threshold, the device moves to REC mode. The corresponding SPI bit is set and the FAULT pin is asserted. Thermal Clusters TH3 (buck), TH5 (boost), TH6 (ldo): in case the temperature reaches the thermal shutdown threshold, the single regulator is shut down. The power stage is switched OFF with a 16 μs filter time. The output decreases and, when the UV is detected, the buck goes in REC state and can be restarted only when the OT flag is reset. The corresponding SPI bit is set and the FAULT pin is asserted. In case the thermal shutdown condition is suspended before the UV is detected, the regulator output turns on again. If the boost or the ldo is not enabled, in case its temperature reaches the thermal shutdown threshold, the corresponding SPI bit is set and the FAULT pin is asserted. Thermal Clusters TH2, TH4: in case the temperature of a cluster reaches the thermal shutdown threshold the corresponding SPI bit is set and the FAULT pin is asserted. Thermal Cluster TH7: in case the temperature of TH7 reaches the thermal shutdown threshold, the corresponding SPI bit is set and the FAULT pin is asserted. STPM066S Voltage regulators and features description DS12976 - Rev 2 page 22/67 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |