전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

S71GS256 데이터시트(PDF) 108 Page - SPANSION

부품명 S71GS256
상세설명  128N based MCPs
PDF  195 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  SPANSION [SPANSION]
홈페이지  http://www.spansion.com
Logo SPANSION - SPANSION

S71GS256 데이터시트(HTML) 108 Page - SPANSION

Back Button S71GS256 Datasheet HTML 104Page - SPANSION S71GS256 Datasheet HTML 105Page - SPANSION S71GS256 Datasheet HTML 106Page - SPANSION S71GS256 Datasheet HTML 107Page - SPANSION S71GS256 Datasheet HTML 108Page - SPANSION S71GS256 Datasheet HTML 109Page - SPANSION S71GS256 Datasheet HTML 110Page - SPANSION S71GS256 Datasheet HTML 111Page - SPANSION S71GS256 Datasheet HTML 112Page - SPANSION Next Button
Zoom Inzoom in Zoom Outzoom out
 108 / 195 page
background image
108
CellularRAM Type 2
cellRAM_00_A0 October 4, 2004
Advan ce
In form ati o n
Bus Operating Modes
CellularRAM products incorporate a burst mode interface found on Flash products
targeting low-power, wireless applications. This bus interface supports asynchro-
nous, page mode, and burst mode read and write transfers. The specific interface
supported is defined by the value loaded into the BCR. Page mode is controlled
by the refresh configuration register (RCR[7]).
Asynchronous Mode
CellularRAM products power up in the asynchronous operating mode. This mode
uses the industry standard SRAM control bus (CE#, OE#, WE#, LB#/ UB#).
READ operations (Figure 23) are initiated by bringing CE#, OE#, and LB#/UB#
LOW while keeping WE# HIGH. Valid data will be driven out of the I/Os after the
specified access time has elapsed. WRITE operations (Figure 24) occur when
CE#, WE#, and LB#/ UB# are driven LOW. During asynchronous WRITE opera-
tions, the OE# level is a “Don't Care,” and WE# will override OE#. The data to be
written is latched on the rising edge of CE#, WE#, or LB#/UB# (whichever occurs
first). Asynchronous operations (page mode disabled) can either use the ADV
input to latch the address, or ADV can be driven LOW during the entire READ/
WRITE operation.
During asynchronous operation, the CLK input must be held static (HIGH or LOW,
no transitions). WAIT will be driven while the device is enabled and its state
should be ignored.
Figure 22. Power-Up Initialization Timing
Note: ADV must remain LOW for page mode operation.
Figure 23. READ Operation (ADV# LOW)
VCC
VCCQ
tPU > 150 µs
Device Initialization
Device ready for
normal operation
VCC = 1.7 V
Data Valid
Address Valid
tRC = READ Cycle Time
CE#
OE#
WE#
ADDRESS
DATA
LB#/UB#
Don't Care



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com