253 / 380 page ![]() Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 253 2015-08-03 OK Parameters See Write Command Response OK or ERROR or +CME ERROR: <err> Write Command AT+CIPCTL=<mod e> Parameters <mode> 0 Disable to send Echo Reply 1 Enable to send Echo Reply to every IP address pinging it 2 Enable to send Echo Reply only to a subset of IP Addresses pinging it. This subset of IP Addresses can be set by “AT+CIPFLT” command. Parameter Saving Mode NO_SAVE Max Response Time - Reference Note The value of <mode> is stored in non volatile memory. 10.2.3 AT+CIPFLT Set the Rules of IP Filter AT+CIPFLT Set the Rules of IP Filter Response +CIPFLT: (list of supported <action>s),(list of supported <item>s) OK Test Command AT+CIPFLT=? Parameters See Write Command Response +CIPFLT: <item>,<ipAddr>,<mask> [<CR><LF>+CIPFLT: <item>,<ipAddr>,<mask> […]] OK Read Command AT+CIPFLT? Parameter See Write Command |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|