| 전자부품 데이터시트 검색엔진 |
|
LTC2414IGN 데이터시트(PDF) 37 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC2414IGN 데이터시트(HTML) 37 Page - Linear Technology |
|
37 / 48 page ![]() LTC2414/LTC2418 37 241418fa The circuit in Figure 42 shows an example of a simple amplification scheme. This example produces a differen- tial output with a common mode voltage of 2.5V, as determined by the bridge. The use of a true three amplifier instrumentation amplifier is not necessary, as the LTC2414/ LTC2418 has common mode rejection far beyond that of most amplifiers. The LTC1051 is a dual autozero amplifier that can be used to produce a gain of 15 before its input referred noise dominates the LTC2414/LTC2418 noise. This example shows a gain of 34, that is determined by a feedback network built using a resistor array containing 8 individual resistors. The resistors are organized to opti- mize temperature tracking in the presence of thermal gradients. The second LTC1051 buffers the low noise input stage from the transient load steps produced during conversion. The gain stability and accuracy of this approach is very good, due to a statistical improvement in resistor match- ing. A gain of 34 may seem low, when compared to common practice in earlier generations of load-cell inter- faces, however the accuracy of the LTC2414/LTC2418 changes the rationale. Achieving high gain accuracy and linearity at higher gains may prove difficult, while provid- ing little benefit in terms of noise reduction. At a gain of 100, the gain error that could result from typical open-loop gain of 160dB is –1ppm, however, worst-case is at the minimum gain of 116dB, giving a gain error of –158ppm. Worst-case gain error at a gain of 34, is –54ppm. The use of the LTC1051A reduces the worst- case gain error to –33ppm. The advantage of gain higher than 34, then becomes dubious, as the input referred noise sees little improvement and gain accuracy is poten- tially compromised. Note that this 4-amplifier topology has advantages over the typical integrated 3-amplifier instrumentation ampli- fier in that it does not have the high noise level common in the output stage that usually dominates when and instru- mentation amplifier is used at low gain. If this amplifier is used at a gain of 10, the gain error is only 10ppm and input referred noise is reduced to 0.1 µVRMS. The buffer stages can also be configured to provide gain of up to 50 with high gain stability and linearity. 0.1 µF 8 0.1 µF 0.1 µF REF+ REF– SDI SCK SD0 CS 20 18 17 16 CH0 CH1 GND VCC FO 11 5VREF 12 350 Ω BRIDGE 21 22 2414/18 F42 15 2 19 LTC2414/ LTC2418 RN1 = 5k × 8 RESISTOR ARRAY U1A, U1B, U2A, U2B = 1/2 LTC1051 – + 3 2 8 4 U1A 4 5V + – 6 5 RN1 1 16 15 2 611 7 1 14 3 710 4 13 89 512 U1B + – 2 3 U2A 5V 1 + – 6 5 U2B 7 Figure 42. Using Autozero Amplifiers to Reduce Input Referred Noise APPLICATIO S I FOR ATIO |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |