28 / 107 page ![]() Integrator low threshold: The integrator such a threshold corresponds to the integrator value at which the PWM toggles from high to low and the output driver switches off. At this point, the load current reaches its max peak level. In variable frequency this level also corresponds to the “F_INTEGRAL” signal at the frequency integrator output. Use this integrator reading to correctly set the “Fint_Start” parameter. Integrator high threshold: The integrator such a threshold corresponds to the integrator value at which the PWM toggles from low to high and the output driver switches on. At this point, the load current reaches its min peak level. In variable frequency this level is zero. Use this integrator reading to verify the correct functionality of the variable frequency algorithm. Integrator minimum level: The minimum current integrator level. Use this integrator reading to correctly set the “NEGINTLIM” parameter. Integrator maximum level: The maximum current integrator level. Use this integrator reading to correctly set the “POSINTLIM” parameter. 6.3.3 Solenoid PWM period feedback The actual PWM time period, whether it is generated by the internal logic in hardware mode or by the INx pins in software mode, is internally measured at each PWM rising edge and provided to the MCU for comparison with the programmed value in register Channel_x.PWMSENSE. It is also checked against the minimum period reference (Tpwm_min) and maximum period reference (Tpwm_max) values. Should the PWM period fall outside these limits, the TMOUT flag is set in SPI register Channel_x.PWMSENSE indicating the control loop is working at an unusual value. If no PWM signal is generated after the maximum reference period (Tpwm_max), the average current is calculated over Tpwm_max period of time. The PWM period is provided using 15 bits with 1µs resolution, providing feedback for periods exceeding Tpwm_max values. The PWM period feedback value is obtained by the formula: PWMPeriod=Cℎannel_x.PWMSENSE.PWMCodeμs (1) • Tpwm_min = 40 µs → fpwm_max = 25 kHz • Tpwm_max = 16.667 ms → fpwm_min = 60 Hz 6.3.4 Out of regulation flag An out of regulation flag is set when the current controller average error is not zero for a time longer than 8 PWM periods, where the PWM period is the programmed PWM period in SPI register Channel_x.CTRLCFG. The flag is independent for each channel and is only available in Hardware Current Control mode. L9305 Current control drivers DS12774 - Rev 10 page 28/107 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |