99 / 184 page ![]() 4.12.4 Operations periodicity While in cyclic execution (CONF_CYCLIC_EN = 1), each step periodicity can be programmed by acting on TCYCLE and NCYCLE_X fields: In case of Cyclic Wake up, the wake up timer is set by TCYCLE_SLEEP instead of TCYCLE. Table 68. TCYCLE and NCYCLE_X options TCYCLE / TCYCLE_SLEEP CYCLE PERIOD NCYCLE_X CYCLIC OCCURRENCE 000 100 ms 000 Excluded from voltage conversion routine 001 200 ms 001 Occurs every 1 cycle 010 400 ms 010 Occurs every 4 cycles 011 800 ms 011 Occurs every 16 cycles 100 1.6 s 100 Occurs every 64 cycles 101 3.2 s 101 Occurs every 128 cycles 110 6.4 s 110 Occurs every 512 cycles 111 12.8 s 111 Occurs every 1024 cycles By combining the two fields, each step periodicity can be evaluated as follows: Evaluation of a step periodicity TSTEP=NCYCLEX×TCYCLE, wℎen not in continuous mode or overflow TSTEP=NCYCLEX×TROUTINE, wℎen in continuous mode or overflow (16) The periodicity ranges from a minimum of 100 ms to a maximum of 3.64 hours (13107.2 s): • Important functional checks such as HWSC might be executed with a high frequency • Time consuming operations such as open load diagnostics might be performed with a low frequency Table 69 lists all the available periodicity options, calculated according to Eq. (16) assuming L9963E is not in continuous mode or overflow: Table 69. Steps periodicity options Tcycle Ncycle 000 001 010 011 100 101 110 111 000 Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled 001 100 ms 200 ms 400 ms 800 ms 1.6 s 3.2 s 6.4 s 12.8 s 010 400 ms 800 ms 1.6 s 3.2 s 6.4 s 12.8 s 25.6 s 51.2 s 011 1.6 s 3.2 s 6.4 s 12.8 s 25.6 s 51.2 s 102.4 s 204.8 s 100 6.4 s 12.8 s 25.6 s 51.2 s 102.4 s 204.8 s 409.6 s 819.2 s 101 12.8 s 25.6 s 51.2 s 102.4 s 204.8 s 409.6 s 819.2 s 1638.4 s 110 51.2 s 102.4 s 204.8 s 409.6 s 819.2 s 1638.4 s 3276.8 s 6553.6 s 111 102.4 s 204.8 s 409.6 s 819.2 s 1638.4 s 3276.8 s 6553.6 s 13107.2 s Changing NCYCLE_X for a step while cyclic activity is enabled (CONF_CYCLIC_EN = 1) will cause the new setting to be applied at the first useful cycle (refer to Table 59). L9963E Voltage conversion routine DS13636 - Rev 12 page 99/184 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |