| 전자부품 데이터시트 검색엔진 |
|
TMP411D 데이터시트(PDF) 28 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP411D 데이터시트(HTML) 28 Page - Texas Instruments |
|
28 / 60 page ![]() Measured Temperature THERM Limit and ALERT High Limit ALERT Low Limit and THERM Limit Hysteresis THERM ALERT SMBus ALERT Read Read Time Read Figure 7-9. SMBus Alert Timing Diagram 7.5.4 Serial Bus Address To communicate with the TMP411-Q1 and TMP411D-Q1, the controller must first address target devices through a target address byte. The target address byte consists of seven address bits and a direction bit that indicates whether the operation is read or write. The addresses of the TMP411A-Q1 and TMP411DA-Q1, and the TMP411D-Q1 and TMP411DD-Q1 devices are 4Ch (1001100b). Table 7-5. TMP411-Q1 and TMP411D-Q1 Device Address Options DEVICE NAME PART NUMBER I2C BINARY ADDRESS I2C HEX ADDRESS DEFAULT LOCAL/ REMOTE HIGH TEMPERATURE LIMIT TMP411-Q1 (DGK package) TMP411AQDGKRQ1 100 1100b 4Ch +85°C TMP411BQDGKRQ1 100 1101b 4Dh +85°C TMP411CQDGKRQ1 100 1110b 4Eh +85°C TMP411DQDGKRQ1 100 1100b 4Ch +110°C TMP411D-Q1 (DDF package) TMP411DAQDDFRQ1 100 1100b 4Ch +85°C TMP411DBQDDFRQ1 100 1101b 4Dh +85°C TMP411DCQDDFRQ1 100 1110b 4Eh +85°C TMP411DDQDDFRQ1 100 1100b 4Ch +110°C 7.5.5 Read/Write Operations To access a particular register on the TMP411-Q1 and TMP411D-Q1, the appropriate value must be written to the Pointer Register. With the read and write bit low, the value for the Pointer Register is the first byte transferred after the target address byte. Every write operation to the TMP411-Q1 and TMP411D-Q1 requires a value for the Pointer Register, as shown in Figure 7-5. When reading from the TMP411-Q1 and TMP411D-Q1 devices, the last value stored in the Pointer Register by a write operation is used to determine which register is read by a read operation. To change the register pointer for a read operation, a new value must be written to the Pointer Register. This transaction is accomplished by issuing a target address byte with the R/W bit low, followed by the Pointer Register byte. No additional data is required. The controller then generates a START condition and sends the target address byte with the R/W bit high to initiate the read command. See Figure 7-6 for details of this sequence. Continually sending the Pointer Register bytes is not necessary if repeated reads from the same register are desired, because the TMP411-Q1 and TMP411D-Q1 devices retain the Pointer Register value until the value is changed by the next write operation. Note that the MSB sends the register bytes first, followed by the LSB. 7.5.6 Time-Out Function When bit 7 of the Consecutive Alert Register is set high, the TMP411-Q1 and TMP411D-Q1 time-out function is enabled. The TMP411-Q1 and TMP411D-Q1 reset the serial interface if either SCL or SDA is held low for 30ms TMP411-Q1, TMP411D-Q1 SBOS527G – DECEMBER 2010 – REVISED SEPTEMBER 2025 www.ti.com 28 Submit Document Feedback Copyright © 2025 Texas Instruments Incorporated Product Folder Links: TMP411-Q1 TMP411D-Q1 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |