| 전자부품 데이터시트 검색엔진 |
|
S5000PAL 데이터시트(PDF) 68 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
S5000PAL 데이터시트(HTML) 68 Page - Intel Corporation |
|
68 / 112 page ![]() Intel ® Server Board S5000PAL / S5000XAL TPS Power and Environmental Specifications Revision 1.7 Intel order number: D31979-010 69 8. Power and Environmental Specifications 8.1 Intel® Server Board S5000PAL / S5000XAL Design Specifications Operation of the server board at conditions beyond those shown in the following table may cause permanent damage to the system. Exposure to absolute maximum rating conditions for extended periods may affect system reliability. Table 33: Server Board Design Specifications Operating Temperature 0º C to 55º C 1 (32º F to 131º F) Non-Operating Temperature -40º C to 70º C (-40º F to 158º F) DC Voltage ± 5% of all nominal voltages Shock (Unpackaged) Trapezoidal, 50 g, 170 inches/sec Shock (Packaged) < 20 lbs ≥ 20 to < 40 ≥ 40 to < 80 ≥ 80 to < 100 ≥100 to < 120 ≥120 36 inches 30 inches 24 inches 18 inches 12 inches 9 inches Vibration (Unpackaged) 5 Hz to 500 Hz 3.13 g RMS random Note: 1 Chassis design must provide proper airflow to avoid exceeding the Dual-Core Intel® Xeon® processor 5000 sequence maximum case temperature. Disclaimer Note : Intel Corporation server boards support add-in peripherals and contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible, if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |