21 / 68 page ![]() October 2004 21 M9999-101204 MIC3000 Micrel Diode Faults The MIC3000 is designed to respond in a failsafe manner to hardware faults in the temperature sensing circuitry. If the connection to the sensing diode is lost or the sense line is shorted to VDD or ground, the temperature data reported by the A/D converter will be forced to its full-scale value (+127°C). The diode fault flag, DFLT, will be set in OEMCFG1, TXFAULT will be asserted, and the high temperature alarm and warning flags will be set. The reported temperature will remain +127°C until the fault condition is cleared. Diode faults may be reset by toggling TXDISABLE, as with any other fault. Diode faults will not be detected at power up until the first A/D conversion cycle is completed. Diode faults are not reported while TXDISABLE is asserted. Temperature Compensation Since the performance characteristics of laser diodes and photodiodes change with operating temperature, the MIC3000 provides a facility for temperature compensation of the A.P.C. loop setpoint, laser modulation current, bias current fault comparator threshold, and bias current high alarm flag thresh- old. Temperature compensation is performed using a look-up table (LUT) that stores values corresponding to each mea- sured temperature over a 128°C span. Four identical tables reside at serial address A4h as summarized in Table 11. The range of temperatures spanned by the tables is program- mable via the LUTOFF register. Each table entry is a signed twos complement number that is used as an offset to the parameter being compensated. The default value of all table entries is zero, giving a flat response. The A/D converter reports a new temperature sample each tCONV. This occurs at roughly 10Hz. To prevent temperature oscillation due to thermal or electrical noise, sixteen succes- sive temperature samples are averaged together and used to index the LUTs. Temperature compensation results are therefore updated at 16 ∞t CONV intervals, or about 1.6 sec- onds. This can be expressed as shown in Equation5. T TT T T 16 COMPm nn 1 n 2 n 15 = + + + ••• ++ + (5) Each time an updated average value is acquired, a new offset value for the APC setpoint is read from the corresponding look-up table (see Table 12) and transferred to the APC circuitry. This is illustrated in Equation 6. In a same way, new offset values are taken from similar look-up tables (see Table 13 and Table 14), added to the nominal values and trans- ferred into the modulation and fault comparator DACs. The bias current high alarm threshold, is compensated using a fourth look-up table (see Table 15). This compensation happens internally and does not affect any host-accessible registers. COUNTER tFLTTMR FLTTMR SATURATION_FAULT Saturation Detector VCOMP 5% VDDA 95% VDDA VDDA Figure 9. Saturation Detector FLTDAC LOSFLT OEMCFG3 LOS DIS CNTRL LOS VRX RXLOS VDDA Figure 10. RXLOS Comparator Logic |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |