| 전자부품 데이터시트 검색엔진 |
|
GETINFOBRIEF 데이터시트(PDF) 23 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
GETINFOBRIEF 데이터시트(HTML) 23 Page - Freescale Semiconductor, Inc |
|
23 / 36 page ![]() Operation MC3PHAC Monolithic Intelligent Motor Controller, Rev. 2 Freescale Semiconductor 23 Maximum voltage $0075 R/W 1 Maximum allowable modulation index value %Maximum voltage = value/$FF $00–$FF VBus voltage (5), (10) $0079 R 2 DC bus voltage reading $000–$3FF Fault timeout $006A R/W 2 Specifies the delay time after a fault condition before re-enabling the motor. Fault timeout = value * 0.262 sec $0000–$FFFF Fault timer $006D R 2 Real-time display of the fault timer Elapsed fault time = value * 0.262 sec $0000–$FFFF VBus decel value (10) $00C9 R/W 2 VBus readings above this value result in reduced deceleration. $0000–$03FF VBus RBRAKE value(10) $0064 R/W 2 VBus readings above this value result in the RBRAKE pin being asserted. $0000–$03FF VBus brownout value(10) $0066 R/W 2 VBus readings below this value result in an under voltage fault. $0000–$03FF VBus over voltage value(10) $0068 R/W 2 VBus readings above this value result in an over voltage fault. $0000–$03FF Speed in ADC value(5) $0095 R 2 Left justified 10-bit ADC reading of the SPEED input pin. $0000–$FFC0 Setup(7) $00AE R 1 Bit field indicating which setup parameters have been initialized before motion is permitted $E0–$FF Switch in(7) $0001 R 1 Bit field indicating the current state of the start/stop and forward/reverse switches $00–$FF Reset status(6), (7) $FE01 R 1 Indicates cause of the last reset $00–$FF Version $EE00 R 4 MC3PHAC version ASCII field 1. The commanded PWM frequency cannot be written until the PWM outputs exit the high-impedance state. The default PWM frequency is 15.873 kHz. 2. The PWM output pins remain in a high-impedance state until this parameter is specified. 3. This parameter must be specified before motor motion can be initiated by the MC3PHAC. 4. This is a write-once parameter. The first write to this address will execute normally. Further attempts at writing this parameter will result in an illegal operation response from the MC3PHAC. 5. The value of this parameter is not valid until the PWM outputs exit the high-impedance state. 6. The data in this field is only valid for one read. Further reads will return a value of $00. 7. See register bit descriptions following this table. 8. Acceleration is an unsigned value with the upper seven bits range of $00 to $7F = acceleration value of 0 to 127 Hertz/second. The lower nine bits constitute the fractional portion of the acceleration parameter. Its range is $000 to $1FF which equals 0 to ~1. Therefore, the range of acceleration is 0 to 127.99 Hertz/second. 9. Commanded motor frequency and actual frequency are signed values with the upper byte range of $00 to $7F = frequency of 0 to 127 Hz. The lower byte is the fractional portion of the frequency. Its range is $00 to $FF which equals 0 to ~1. 10. VBus is the voltage value applied to the DC_BUS analog input pin. The analog-to-digital converter is a 10-bit converter with a 5 volt full scale input. The value is equal to the voltage applied to the DC_BUS input pin/VREF * $03FF. Table 6. User Interface Variables for Use with PC Master Software (Continued) Name Address Read/ Write Size (Bytes) Description Valid Data |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |